Key result
Tip-PVD echocardiography improves right ventricular output accuracy over hinge-PVD, reducing measurement bias to ~1.4 mL/kg/min.
Why the study?
The study aimed to evaluate the accuracy and reproducibility of calculating right ventricular output using different anatomical landmarks for pulmonary valve diameter in neonates.
Does right ventricular output calculation using pulmonary valve diameter measured at the leaflet tips improve accuracy compared to the conventional hinge points method in neonates?
Observational (n=45)
Single-blind
No
Does right ventricular output calculation using pulmonary valve diameter measured at the leaflet tips improve accuracy compared to the conventional hinge points method in neonates?
Measuring pulmonary valve diameter at the leaflet tips rather than the traditional hinge points significantly improves the accuracy of right ventricular output calculation in neonates.
We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included. Accuracy was assessed by comparison with LVO. Intra- and inter-observer reproducibility of the off-line analysis were assessed. Forty-five neonates were included. RVO calculation with tip-PVD was more accurate than hinge-PVD in comparison with LVO, r2 0.712 versus 0.464, bias (95% limits of agreement) 1.4 mL/kg/min (−26–29 mL/kg/min) versus 61 mL/kg/min (−11–132 mL/kg/min), respectively. Both hinge-PVD and tip-PVD presented similar reproducibility, with an intra-observer bias (95% LOA) of 0.3 (−1.0–0.5) and –0.2 (−0.8–0.5) respectively, and an inter-observer bias of 0.1 (−1.3–1.6) and 0.1 (−1.4–1.6). RVO calculation using tip-PVD was more accurate than the conventional technique, with similar reproducibility.
No takes yet. Share an insight, caveat, or question.
Milocchi et al. (2025) conducted an observational in Healthy neonates (n=45). Tip-PVD (diameter between pulmonary valve leaflet tips) vs. Hinge-PVD (diameter between valve hinge points) was evaluated on Accuracy (bias) of right ventricular output (RVO) calculation compared to left ventricular output (LVO) (bias 1.4 mL/kg/min, 95% CI -26 to 29). Right ventricular output calculation using tip-PVD was more accurate than the conventional hinge-PVD technique, demonstrating a bias of 1.4 mL/kg/min versus 61 mL/kg/min compared to left ventricular output.