Key result
Novel RVOT Doppler notch analysis strongly correlates with invasive PVR.
Why the study?
RHC is the gold standard for measuring PVR, but current noninvasive methods lack accuracy, especially in moderate to severe pulmonary arterial hypertension.
Does a novel echocardiographic method using right ventricular outflow tract Doppler notch analysis accurately estimate pulmonary vascular resistance compared to invasive measurement in patients undergoing right heart catheterization?
Observational (n=54)
No
Does a novel echocardiographic method using right ventricular outflow tract Doppler notch analysis accurately estimate pulmonary vascular resistance compared to invasive measurement in patients undergoing right heart catheterization?
A novel echocardiographic method using right ventricular outflow tract Doppler notch analysis provides a feasible and reliable noninvasive estimation of pulmonary vascular resistance that correlates strongly with invasive measurements.
Answers are grounded in this paper and cite their sources.
May support noninvasive PVR estimation; leaves open prospective validation before clinical adoption.
BACKGROUND: Right heart catheterization (RHC) is the gold standard for measuring pulmonary vascular resistance (PVR). Current noninvasive methods lack accuracy, especially in moderate to severe pulmonary arterial hypertension. OBJECTIVES: The objective of the study was to develop and validate a novel echocardiographic method for estimating PVR using right ventricular outflow tract Doppler notch analysis. METHODS: In this prospective study, of 95 patients undergoing RHC, 35 with isolated postcapillary pulmonary hypertension (PVR <2.0 WU) and no discernible Doppler notches were excluded. Of the remaining, 54 patients with interpretable Dopplers were divided into derivation (n = 30) and validation (n = 24) cohorts, all undergoing invasive PVR (iPVR) measurement and echocardiography within 24 hours. Right ventricular outflow tract Doppler, specifically the ratio of notch time (NT) to ejection time, was analyzed to derive a regression equation for non-invasive PVR (niPVR). The model was validated against iPVR and compared with 5 existing methods. Validation against 5 established methods showed superior performance across a PVR range of 2.3 to 14.2 WU, with the highest Pearson correlation (r: 0.76; P < 0.0001; 95% CI: 0.52-0.89). Bland-Altman analysis confirmed superior agreement. CONCLUSIONS: This novel echocardiographic method offers feasible, rapid, reliable PVR estimation with strong correlation to invasive measurements. Although not a substitute for RHC, this promising preliminary finding from a selective cohort may aid in identifying candidates for invasive testing and guide pulmonary hypertension management. Larger, multicenter validation is warranted.
No takes yet. Share an insight, caveat, or question.
Afonso et al. (2025) conducted an observational in Pulmonary hypertension (n=54). Noninvasive estimation of PVR using right ventricular outflow tract Doppler notch analysis vs. Invasive PVR measurement (RHC) and 5 existing echocardiographic methods was evaluated on Correlation between noninvasive PVR and invasive PVR (Pearson correlation r: 0.76, 95% CI 0.52-0.89, p=< 0.0001). A novel echocardiographic method using right ventricular outflow tract Doppler notch analysis strongly correlated with invasive pulmonary vascular resistance.
Synapse has enriched 10 related papers. Consider them for comparative context: