Key result
4D echocardiographic assessment of fetal right ventricular volume and function using TOMTEC 4D RV-Function software was feasible in 83% of healthy fetuses.
Why the study?
Evaluation of the fetal right ventricle using standard 2D echocardiography is challenging due to complex geometry, prompting assessment of the feasibility of 4D echocardiographic volumetric and strain analysis.
Is 4D echocardiographic assessment of the fetal right ventricle using TOMTEC 4D RV-Function software feasible?
Observational (n=46)
No
Is 4D echocardiographic assessment of the fetal right ventricle using TOMTEC 4D RV-Function software feasible?
4D echocardiographic assessment of the fetal right ventricle is feasible in the majority of cases, providing a novel method for evaluating volumetric and functional parameters.
Feasibility of fetal 4D RV analysis shown; leaves open validation of accuracy and clinical utility.
Functional analysis of the fetal cardiovascular system is crucial for the assessment of fetal condition. Evaluation of the right ventricle with standard 2D echocardiography is challenging due to its complex geometry and irregular muscle fibers arrangement. Software package TOMTEC 4D RV-Function is an analysis tool which allows assessment of right ventricular function based on volumetric measurements and myocardial deformation. The aim of this study was to determine the feasibility of this method in fetal echocardiography. The retrospective study was conducted in the high-flow Referral Center for Fetal Cardiology. We recorded 4D echocardiographic sequences of 46 fetuses with normal hearts. Following parameters were calculated: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF), right ventricle longitudinal free-wall (RVLS free-wall) and septal strain (RVLS septum). Tei index was calculated as a standard measure or RV function for comparison. 4D assessment was feasible in 38 out of 46 fetuses (83%). RV volumetric parameters-EDV, ESV and SV-increased exponentially with gestational age. Functional parameters-RV Tei index, EF and strains-were independent of gestational age. Mean EF was 45.2% (± 6%), RV free-wall strain was - 21.2% and RV septal strain was - 21.5%. There was a statistically significant correlation between septal and free-wall strains (r = 0.51, p = 0.001) as well as between EF and RV free-wall strain (r = - 0.41, p = 0.011). 4D RV assessment is feasible in most fetuses. Its clinical application should be further investigated in larger prospective studies.
No takes yet. Share an insight, caveat, or question.
Pasieczna et al. (2021) conducted an observational in Normal fetal hearts (n=46). 4D echocardiography using TOMTEC 4D RV-Function software was evaluated on Feasibility of 4D RV assessment. 4D echocardiographic assessment of fetal right ventricular volume and function using TOMTEC 4D RV-Function software was feasible in 83% of healthy fetuses.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: