Key result
Real-time 3-dimensional echocardiography was feasible for assessing ventricular volume, mass, and function in 88% of normal fetuses and 43% of fetuses with congenital heart disease.
Why the study?
Is real-time 3-dimensional echocardiography (RT3DE) feasible and reproducible for assessing ventricular volume, mass, and function in human fetuses?
Observational (n=80)
Single-blind
No
Is real-time 3-dimensional echocardiography (RT3DE) feasible and reproducible for assessing ventricular volume, mass, and function in human fetuses?
Real-time 3-dimensional echocardiography is a feasible and reproducible modality for assessing fetal ventricular volume, mass, and function, demonstrating exponential gestational growth of these parameters in normal fetuses.
Answers are grounded in this paper and cite their sources.
Supports RT3DE feasibility for fetal ventricular assessment; leaves open clinical adoption in congenital heart disease pending validation.
OBJECTIVES: We sought to determine the feasibility and reproducibility of real-time 3-dimensional echocardiography (RT3DE) for evaluation of cardiac volume, mass, and function and to characterize maturational changes of these measurements in human fetuses. METHODS: Eighty pregnant women in the 2(nd) and 3(rd) trimesters (59 with normal fetuses and 21 with fetuses with congenital heart disease [CHD]) were enrolled. We acquired RT3DE images using a matrix-array transducer. RT3DE measurements of volume, mass, stroke volume (SV), combined cardiac output (CCO), and ejection fraction (EF) were obtained. Images were scored and analyzed by two blinded independent observers. Inter- and intraobserver variabilities and correlations between fetal cardiac indices and gestational age were determined. RESULTS: Fifty-two of 59 normal data sets (88%) and 9 of 21 CHD data sets (43%) were feasible for analysis. In normal fetuses, the right ventricle (RV) is larger than the left ventricle (LV) (P<0.05), but no difference exists between the LV and RV in mass, SV, CO, and CO/CCO. The EFs for the LV and RV were diminished; the RVSV/LVSV was reduced in CHD fetuses compared with normal fetuses (P<0.05). Fetal ventricular volumes, mass, SV, and CCO fit best into exponential curves with gestational age, but LVEF, RVEF, and RVSV/LVSV remain relatively constant. CONCLUSIONS: RT3DE is feasible and reproducible for assessment of LV and RV volume, mass, and function, especially in normal fetuses. Gestational growth of these measures, except for EF, is exponential in normal and CHD fetuses. CHD fetuses exhibit diminished LV and RV EFs.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2013) conducted an observational in Normal fetuses and fetuses with congenital heart disease (n=80). Real-time 3-dimensional echocardiography (RT3DE) was evaluated on Feasibility of RT3DE data sets for analysis in normal fetuses. Real-time 3-dimensional echocardiography was feasible for assessing ventricular volume, mass, and function in 88% of normal fetuses and 43% of fetuses with congenital heart disease.
Synapse has enriched 10 related papers. Consider them for comparative context: