Key result
Nongated real-time three-dimensional echocardiography demonstrated excellent correlation with reference values for quantifying stroke volume, LV mass, and myocardial strain in fetal-sized hearts (all P<0.05).
Why the study?
Does nongated real time three-dimensional echocardiography accurately measure stroke volume, mass, and myocardial strain in fetal-sized hearts compared to reference methods?
Does nongated real time three-dimensional echocardiography accurately measure stroke volume, mass, and myocardial strain in fetal-sized hearts compared to reference methods?
Effect estimate: R2 ≥ 0.76 to 0.98
p-value: p=< 0.05
Nongated real-time three-dimensional echocardiography accurately quantifies stroke volume, left ventricular mass, and myocardial strain in fetal-sized hearts, suggesting potential utility for evaluating fetal cardiac function.
Hypothesis-generating in animal models; leaves open translation to human fetal echocardiography.
BACKGROUND: Left ventricular stroke volume, mass, and myocardial strain are valuable indicators of fetal heart function. This study investigated the feasibility of nongated real time three-dimensional echocardiography (RT3DE) to determine fetal stroke volume (SV), left ventricular mass (LVM), and myocardial strain under different conditions. METHODS: To evaluate fetal hearts, fetal-sized rabbit hearts were used in this study. The in vitro portion of this study was carried out using a balloon inserted into the LV of eight fresh rabbit hearts and driven by a calibrated pulsatile pump. RT3DE volumes were obtained at various pump-set SVs. The in vivo experiments in this study were performed on open-chest rabbits. RT3DE volumes were acquired at the following conditions: baseline, simulated hypervolemia, inferior vena cava (IVC) ligation, and ascending aorta (AAO) ligation. Displacement values and sonomicrometry data were used as references for RT3DE-derived SV, LVM, longitudinal strain (LS), and circumferential strain (CS). RESULTS: Excellent correlations between RT3DE-derived values and reference values were demonstrated and accompanied by high coefficients of determination (R(2) ) for both in vitro and in vivo studies for SV, LVM, LS, and CS (in vitro: SV: R(2) = 0.98; LVM: R(2) = 0.97; LS: R(2) = 0.87, CS: R(2) = 0.80; in vivo: SV: R(2) = 0.92; LVM: R(2) = 0.98; LS: in vivo: R(2) = 0.84; CS: in vivo: R(2) = 0.76; all P < 0.05). CONCLUSIONS: RT3DE is capable of quantifying the SV, LVM, and myocardial strain of fetal-sized hearts under different conditions. This nongated RT3DE may aid the evaluation of fetal cardiac function, providing a superior understanding of the progress of fetal heart disorders.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2015) studied Fetal heart function evaluation (n=8). Nongated real time three-dimensional echocardiography (RT3DE) vs. Displacement values and sonomicrometry data (reference) was evaluated on Correlation between RT3DE-derived values and reference values for SV, LVM, LS, and CS (R2 ≥ 0.76 to 0.98, p=< 0.05). Nongated real-time three-dimensional echocardiography demonstrated excellent correlation with reference values for quantifying stroke volume, LV mass, and myocardial strain in fetal-sized hearts (all P<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: