Key result
Adding intrathoracic impedance measurements to clinical variables improved the classification of 30-day heart failure rehospitalization (net reclassification index 0.42; 95% CI 0.10-0.74).
Why the study?
The study aimed to improve in-person clinical evaluation on the day of HF hospitalization discharge by adding device-measured parameters to predict 30-day HF rehospitalization risk in CRT-D patients.
Does the addition of device-measured parameters improve the prediction of 30 day heart failure rehospitalization in CRT-D patients compared to clinical parameters alone?
Cohort (n=1,563)
Yes
Does the addition of device-measured parameters improve the prediction of 30 day heart failure rehospitalization in CRT-D patients compared to clinical parameters alone?
The addition of device-measured intrathoracic impedance to standard clinical evaluation significantly improves the prediction of 30-day heart failure rehospitalization in patients with CRT-D devices.
Answers are grounded in this paper and cite their sources.
Impedance may aid 30-day HF rehospitalization classification; hypothesis-generating and requires prospective validation before adoption.
AIMS: This study aimed to improve in-person clinical evaluation on the day of heart failure (HF) hospitalization discharge by adding device-measured parameters to predict 30 day HF rehospitalization risk in cardiac resynchronization therapy-defibrillator (CRT-D) patients. METHODS AND RESULTS: In a cohort of Medicare patients with CRT-Ds, the independent prognostic value of four device-measured parameters was assessed relative to typical clinical parameters associated with rehospitalization risk. Medicare registry, claims, and Medtronic CareLink® Network data for these patients were analysed using logistic regression modelling and net reclassification methods. Among 1563 CRT-D patients, 411 patients had 607 HF hospitalization events during a median 6.3 years of follow-up. Compared with clinical variables alone, impedance measurements resulted in a 28% improvement between the predicted probabilities of having vs. not having a 30 day HF rehospitalization (relative integrated discrimination improvement = 0.28) and a net 42% improvement in the classification of 30 day HF rehospitalization events and non-events after an index HF hospitalization (net reclassification index = 0.42; 95% CI: 0.10, 0.74). CONCLUSIONS: In CRT patients, intrathoracic impedance measurements improve prediction of 30 day HF rehospitalization over clinical characteristics alone. The present study provides supportive data for the routine evaluation of intrathoracic impedance prior to discharge in patient with CRT devices. Furthermore, the models developed in this study could be used to design interventions to improve compliance with Medicare reimbursement guidelines regarding 30 day HF rehospitalization.
No takes yet. Share an insight, caveat, or question.
Brown et al. (2020) conducted a cohort in Heart failure (n=1,563). Intrathoracic impedance measurements vs. Clinical variables alone was evaluated on 30 day heart failure rehospitalization (net reclassification index 0.42, 95% CI 0.10-0.74). Adding intrathoracic impedance measurements to clinical variables improved the classification of 30-day heart failure rehospitalization (net reclassification index 0.42; 95% CI 0.10-0.74).