Key result
A clinical risk score using CRT device diagnostics successfully classified patients into low, moderate, and high risk of death.
Why the study?
Can measured diagnostic variables in CRT devices predict mortality in patients receiving cardiac resynchronization therapy?
Cohort (n=1,274)
Can measured diagnostic variables in CRT devices predict mortality in patients receiving cardiac resynchronization therapy?
Diagnostic variables measured by CRT devices can be used to create a validated clinical risk score that effectively predicts mortality in patients receiving cardiac resynchronization therapy.
Answers are grounded in this paper and cite their sources.
May support device-based risk stratification in CRT recipients; hypothesis-generating pending prospective validation.
AIMS: This retrospective analysis sought to develop and validate a model using the measured diagnostic variables in cardiac resynchronization therapy (CRT) devices to predict mortality. METHODS AND RESULTS: Data used in this analysis came from two CRT studies: Cardiac Resynchronization Therapy Registry Evaluating Patient Response with RENEWAL Family Devices (CRT RENEWAL) (n = 436) and Heart Failure-Heart Rate Variability (HF-HRV) (n = 838). Patients from CRT RENEWAL were used to create a model for risk of death using logistic regression and to create a scoring system that could be used to predict mortality. Results of both the logistic regression and the clinical risk score were validated in a cohort of patients from the HF-HRV study. Diagnostics significantly improved over time post-CRT implant (all P < 0.001) and were correlated with a trend of decreased risk of death. The regression model classified CRT RENEWAL patients into low (2.8%), moderate (6.9%), and high (13.8%) risk of death based on tertiles of their model predicted risk. The clinical risk score classified CRT RENEWAL patients into low (2.8%), moderate (10.1%), and high (13.4%) risk of death based on tertiles of their score. When both the regression model and the clinical risk score were applied to the HF-HRV study, each was able to classify patients into appropriate levels of risk. CONCLUSION: Device diagnostics may be used to create models that predict the risk of death.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2009) conducted a cohort in Heart failure requiring cardiac resynchronization therapy (n=1,274). Device diagnostics risk model was evaluated on Mortality. A clinical risk score using CRT device diagnostics successfully classified patients into low, moderate, and high risk of death.
Synapse has enriched 10 related papers. Consider them for comparative context: