Key result
Prolonged active-fixation temporary RV pacing permits safe AV conduction recovery in ICIMy with complete heart block.
Why the study?
Mortality from immune checkpoint inhibitor associated myocarditis is high, and developing advanced atrioventricular block is associated with worse mortality.
Does temporary pacing with an active fixation right ventricular lead and external generator safely bridge patients with immune checkpoint myocarditis and complete heart block to AV conduction recovery?
Cohort (n=103)
No
Does temporary pacing with an active fixation right ventricular lead and external generator safely bridge patients with immune checkpoint myocarditis and complete heart block to AV conduction recovery?
Active fixation RV leads with external generators offer a safe, prolonged temporary pacing strategy to bridge patients with ICIMy and complete heart block to AV conduction recovery, avoiding unnecessary permanent pacemakers.
Answers are grounded in this paper and cite their sources.
May support temporary pacing with active fixation leads in ICIMy-related heart block; hypothesis-generating and requires prospective validation.
Myocarditis is a rare but serious immune-related adverse event associated with immune checkpoint inhibitors. Mortality from immune checkpoint inhibitor associated myocarditis (ICIMy) is high, and developing advanced atrioventricular block is associated with worse mortality. Among a single-center cohort of 103 patients diagnosed with ICIMy, we describe 9 patients who required cardiac pacing for complete heart block. We present our systematic approach to managing ICIMy with advanced atrioventricular block, emphasizing the use of an active fixation right ventricular lead and external pacemaker generator for temporary pacing. This allows for stable and prolonged temporary pacing over a period of 4 to 6 weeks before deciding on implantation of a permanent pacemaker. This strategy has the potential to minimize infection risk by avoiding the need for generator pocket formation while patients are undergoing immunosuppressive therapy for treatment of ICIMy and allows for patient mobility and participation in physical therapy.
No takes yet. Share an insight, caveat, or question.
Palaskas et al. (2025) conducted a cohort in Immune checkpoint inhibitor associated myocarditis (ICIMy) with complete heart block (n=103). Active fixation right ventricular lead with external pacemaker generator vs. Balloon-tipped transvenous pacing catheter or pharmacologic pacing (descriptive) was evaluated on Recovery of atrioventricular (AV) conduction (Median 18 days to recovery). An active fixation right ventricular lead with an external generator allowed safe, prolonged temporary pacing and recovery of AV conduction in patients with ICIMy and complete heart block.