Key result
Transthoracic ultrafast Doppler imaging successfully mapped intraventricular transient flows with millisecond resolution and quantified 2-D flow propagation velocity without the use of contrast agents.
Why the study?
Can transthoracic ultrafast Doppler imaging effectively map 2-D human left ventricular blood flow patterns during the whole cardiac cycle?
Observational (n=2)
No
Can transthoracic ultrafast Doppler imaging effectively map 2-D human left ventricular blood flow patterns during the whole cardiac cycle?
Transthoracic ultrafast Doppler imaging demonstrates superior sensitivity and temporal resolution, making it a promising noninvasive tool for studying intraventricular hemodynamics.
Enables full-cycle 2D LV flow mapping in humans; leaves open clinical utility pending prospective validation.
Heart diseases can affect intraventricular blood flow patterns. Real-time imaging of blood flow patterns is challenging because it requires both a high frame rate and a large field of view. To date, standard Doppler techniques can only perform blood flow estimation with high temporal resolution within small regions of interest. In this work, we used ultrafast imaging to map in 2-D human left ventricular blood flow patterns during the whole cardiac cycle. Cylindrical waves were transmitted at 4800 Hz with a transthoracic phased-array probe to achieve ultrafast Doppler imaging of the left ventricle. The high spatio-temporal sampling of ultrafast imaging permits reliance on a much more effective wall filtering and increased sensitivity when mapping blood flow patterns during the pre-ejection, ejection, early diastole, diastasis, and late diastole phases of the heart cycle. The superior sensitivity and temporal resolution of ultrafast Doppler imaging makes it a promising tool for the noninvasive study of intraventricular hemodynamic function.
No takes yet. Share an insight, caveat, or question.
Osmanski et al. (2014) conducted an observational in Left ventricular hemodynamic function (n=2). Transthoracic ultrafast Doppler imaging vs. Conventional color M-mode (for flow propagation velocity comparison) was evaluated on Mapping of 2-D human left ventricular blood flow patterns and quantification of flow propagation velocity. Transthoracic ultrafast Doppler imaging successfully mapped intraventricular transient flows with millisecond resolution and quantified 2-D flow propagation velocity without the use of contrast agents.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: