Key result
The plasma/urinary N-BNP product yielded a high ROC-AUC (0.923) and specificity (78%) for detecting left ventricular systolic dysfunction, reducing the number of echocardiograms needed to detect one case to 11.4.
Why the study?
Plasma N-BNP is elevated in LVSD and renal tubule cells produce BNP, prompting evaluation of the incremental value of urinary N-BNP in LVSD diagnosis.
Cross-Sectional (n=1,308)
Answers are grounded in this paper and cite their sources.
May support community natriuretic peptide screening for LV dysfunction; hypothesis-generating, needs randomized confirmation before practice change.
OBJECTIVES We sought to compare urinary and plasma N-terminal pro-brain natriuretic peptide (N-BNP) in left ventricular systolic dysfunction (LVSD) diagnosis. BACKGROUND Plasma N-BNP is elevated in LVSD. Renal tubule cells produce BNP. We tested the incremental value of urinary N-BNP in LVSD diagnosis. METHODS In this prospective, community-screening study of undiagnosed LVSD, 1,360 subjects (45 to 80 years of age) were invited, and 1,308 had analyzable echocardiographic scans and urine and plasma specimens. The criterion standard for LVSD was defined as a wall motion score over 1.8 (ejection fraction < or =40%). RESULTS Twenty-eight patients with LVSD had elevated urinary and plasma N-BNP levels compared with normal subjects (p < 0.0005). Receiver-operating characteristic (ROC) areas under the curve (AUCs) for urinary and plasma N-BNP were 0.831 and 0.840, respectively. Both tests had high negative predictive values (>99%) for excluding LVSD. Urinary N-BNP was more specific (67.2%) than plasma N-BNP (41%). The plasma/urinary N-BNP product yielded a higher ROC-AUC (0.923) and specificity (78%), reducing the number of cases to scan to detect one case of LVSD to 11.4 (compared with 16.6 [urinary N-BNP] and 29.0 [plasma N-BNP]). Sequential application of tests (urinary N-BNP, then plasma N-BNP in the urine-"positive" cases) achieved similar reductions in the number of cases to scan (10.8), while limiting the number of N-BNP tests to be performed. Urinary N-BNP performed poorly in detection of other cardiac abnormalities with preserved systolic function. It was less costly to test urinary N-BNP in the whole population as compared with other strategies, including scanning high-risk cases with N-BNP testing in the remainder. CONCLUSIONS Urinary N-BNP used together with plasma N-BNP could reduce the echocardiographic burden in screening programs.
No takes yet. Share an insight, caveat, or question.
Ng et al. (2005) conducted a cross-sectional in undiagnosed left ventricular systolic dysfunction (n=1,308). Urinary and plasma N-BNP testing vs. Echocardiography was evaluated on Diagnosis of left ventricular systolic dysfunction (ejection fraction ≤40%) (ROC-AUC 0.923, p=< 0.0005). The plasma/urinary N-BNP product yielded a high ROC-AUC (0.923) and specificity (78%) for detecting left ventricular systolic dysfunction, reducing the number of echocardiograms needed to detect one case to 11.4.
Synapse has enriched 10 related papers. Consider them for comparative context: