Key result
A multidisciplinary pulmonary vein contouring atlas led to reproducible delineation for radiotherapy planning, achieving an overall mean Dice similarity coefficient of 0.80 compared to reference contours.
Why the study?
Arrhythmogenic pulmonary veins are not currently considered organs-at-risk during radiotherapy planning, and a standardised approach to their delineation was needed.
A multidisciplinary pulmonary vein atlas enables reproducible delineation for radiotherapy planning, which may facilitate future research on radiation-induced arrhythmias.
Answers are grounded in this paper and cite their sources.
May aid consistent pulmonary vein sparing during lung cancer radiotherapy; leaves open clinical outcome benefits pending validation.
BACKGROUND AND PURPOSE: Cardiac arrhythmia is a recognised potential complication of thoracic radiotherapy, but the responsible cardiac substructures for arrhythmogenesis have not been identified. Arrhythmogenic tissue is commonly located in the pulmonary veins (PVs) of cardiology patients with arrhythmia, however these structures are not currently considered organs-at-risk during radiotherapy planning. A standardised approach to their delineation was developed and evaluated. MATERIALS AND METHODS: The gross and radiological anatomy relevant to atrial fibrillation was derived from cardiology and radiology literature by a multidisciplinary team. A region of interest and contouring instructions for radiotherapy computed tomography scans were iteratively developed and subsequently evaluated. Radiation oncologists (n = 5) and radiation technologists (n = 2) contoured the PVs on the four-dimensional planning datasets of five patients with locally advanced lung cancer treated with 1.8-2.75 Gy fractions. Contours were compared to reference contours agreed by the researchers using geometric and dosimetric parameters. RESULTS: The mean dose to the PVs was 35% prescription dose. Geometric and dosimetric similarity of the observer contours with reference contours was fair, with an overall mean Dice of 0.80 ± 0.02. The right superior PV (mean DSC 0.83 ± 0.02) had better overlap than the left (mean DSC 0.80 ± 0.03), but the inferior PVs were equivalent (mean DSC of 0.78). The mean difference in mean dose was 0.79 Gy ± 0.71 (1.46% ± 1.25). CONCLUSION: A PV atlas with multidisciplinary approval led to reproducible delineation for radiotherapy planning, supporting the utility of the atlas in future clinical radiotherapy cardiotoxicity research encompassing arrhythmia endpoints.
No takes yet. Share an insight, caveat, or question.
Walls et al. (2023) studied Locally advanced lung cancer (n=5). Pulmonary vein contouring atlas vs. Reference contours was evaluated on Mean Dice similarity coefficient (DSC) of observer contours compared to reference contours. A multidisciplinary pulmonary vein contouring atlas led to reproducible delineation for radiotherapy planning, achieving an overall mean Dice similarity coefficient of 0.80 compared to reference contours.
Synapse has enriched 10 related papers. Consider them for comparative context: