Answers are grounded in this paper and cite their sources.
Randomized trial compares narrow- and wide-diameter implants for molar replacement, indicating non-inferiority in bone loss.
Aim To compare 1‐year clinical and radiographic outcomes of narrow‐ versus wide‐diameter tissue‐level implants for single molar replacement. Materials and Methods This two‐arm randomised controlled trial enrolled 20 patients (23 implants) in one sextant. Participants received either 3.5‐mm narrow‐diameter implants (NDI, n = 12) or 5.0‐mm wide‐diameter implants (WDI, n = 11) using a tissue‐level design with computer‐guided surgery. The primary outcome was marginal bone loss (MBL) at 1 year assessed by periapical radiographs. Secondary outcomes included operation time, pre‐allocation analysis of augmentation requirement, clinical peri‐implant parameters, hard‐ and soft‐tissue dimensions, mucosal recession and buccal soft‐tissue contour and implant stability. Non‐inferiority margin for MBL was 0.5 mm. Results All 23 implants achieved 100% survival. Mean MBL was 0.39 ± 0.29 mm for NDI and 0.48 ± 0.31 mm for WDI (upper 95% confidence interval [CI]: 0.176 mm), confirming non‐inferiority of NDI. Operation time was shorter in this cohort for NDI (20.3 ± 9.3 min) than WDI (28.8 ± 15.3 min; one‐sided p = 0.049). Peri‐implant clinical parameters were comparable. Conclusions NDI showed non‐inferiority to WDI in MBL at 1 year while reducing operative time, supporting NDIs as a viable and efficacious alternative for anatomically restricted posterior sites. Trial Registration Korean ClinicalResearch Information Service Number: KCT00094155
No takes yet. Share an insight, caveat, or question.
Park et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: