Key result
This review details motion artifact mechanisms in capacitive electrocardiogram systems and provides an overview of mitigation approaches using materials, analog circuits, and digital signal processing.
Why the study?
Capacitive electrocardiogram systems offer advantages over conventional ECGs but are more prone to motion artifacts that can overlap with ECG signals or saturate electronics.
This review outlines current engineering and signal processing strategies to mitigate motion artifacts in capacitive ECG systems, which are crucial for advancing wearable cardiac monitoring.
cECG motion artifact vulnerability warrants caution in clinical monitoring; leaves open need for robust mitigation validation in prospective studies.
Capacitive electrocardiogram (cECG) systems are increasingly used for the monitoring of cardiac activity. They can operate within the presence of a small layer of air, hair or cloth and do not require a qualified technician. They can be integrated into wearables, clothing or objects of daily life, such as beds or chairs. While they offer many advantages over conventional electrocardiogram systems (ECG) that rely on wet electrodes, they are more prone to be affected by motion artifacts (MAs). These effects, which are due to the relative movement of the electrode in relation to the skin, are several orders of magnitude higher than ECG signal amplitudes, they occur in frequencies that might overlap with the ECG signal, and they may saturate the electronics in the most severe cases. In this paper, we provide a detailed description of MA mechanisms that translate into capacitance variations due to electrode-skin geometric changes or into triboelectric effects due to electrostatic charge redistribution. A state-of-the-art overview of the different approaches based on materials and construction, analog circuits and digital signal processing is provided as well as the trade-offs to be made using these techniques, to mitigate MAs efficiently.
No takes yet. Share an insight, caveat, or question.
Sirtoli et al. (2023) conducted a review in Cardiac activity monitoring. Capacitive electrocardiogram (cECG) motion artifact removal techniques was evaluated. This review details motion artifact mechanisms in capacitive electrocardiogram systems and provides an overview of mitigation approaches using materials, analog circuits, and digital signal processing.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: