This paper presents the design of a novel flexure-based precision positioning stage with constant output force for biological cell micromanipulation. One uniqueness of the proposed design is that it produces a constant force without using a force controller. Only a motion control is needed to produce a constant output force, which significantly simplifies the system design process. The stage is driven by a piezoelectric actuator through a displacement amplifier. Analytical models of the displacement amplifier and the zero-stiffness structure are established and verified by conducting finite-element analysis simulations. The structure parameters are optimally designed to guarantee the requirement on output force, motion range, and physical size. A prototype stage is fabricated by 3-D printing process and a series of experiments is carried out. Experimental results show that the developed positioning stage delivers a near constant output force with slight fluctuation in the reachable constant-force motion range of 138 μm. The applications of the developed constant-force stage in biological cell manipulation have been demonstrated through experimental investigations.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: