Key result
Varying the activation wavefront during pacing revealed that scar characteristics are dependent on the wavefront, with only 44.6% overlap in voltage maps between different pacing sites.
Answers are grounded in this paper and cite their sources.
This editorial highlights that bipolar voltage and electrogram characteristics in ischemic scar are highly dependent on the activation wavefront, suggesting that multi-site pacing may be necessary to accurately identify critical VT isthmuses during substrate-based ablation.
HomeCirculation: Arrhythmia and ElectrophysiologyVol. 12, No. 6Scar Anisotropy Free AccessEditorialPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessEditorialPDF/EPUBScar AnisotropyWhat Can Varying Wavefronts of Ventricular Activation Tell Us About the Physiology of Reentry Circuits? Pierre Qian, BSc(med), MBBS and Usha Tedrow, MD, MSc Pierre QianPierre Qian Cardiovascular Division, Brigham and Women's Hospital, Boston, MA. and Usha TedrowUsha Tedrow Usha Tedrow, MD, MSc, Cardiovascular Division, Brigham and Women's Hospital, 75 Francis St, Boston, MA 02115. Email E-mail Address: [email protected] Cardiovascular Division, Brigham and Women's Hospital, Boston, MA. Originally published24 May 2019https://doi.org/10.1161/CIRCEP.119.007457Circulation: Arrhythmia and Electrophysiology. 2019;12:e007457This article is a commentary on the followingEffect of Activation Wavefront on Electrogram Characteristics During Ventricular Tachycardia AblationSee Article by Martin et alSubstrate for ventricular tachycardia (VT) in structural heart disease is often related to surviving poorly coupled myocytes in regions of fibrosis. Alterations in local conduction velocity can be dependent on properties of the myocytes and gap junctions, as well as fibroblasts and collagen. These abnormal areas have been demonstrated to exhibit fractionation and late potentials on bipolar mapping,1 particularly when interrogated with small electrode mapping catheters. The development of substrate-based VT catheter ablation techniques, predominantly from cohorts with ischemic cardiomyopathy, have allowed identification of areas in fibrotic scar likely to form critical portions of VT circuits during sinus or paced rhythm. Areas of low voltage, late potentials, and slowed conduction can be targeted for catheter ablation. Substrate mapping and ablation techniques have led to successful catheter ablation of hemodynamically unstable VTs that could otherwise not be mapped safely or easily during tachycardia. However, long-term VT-free survival after catheter ablation in patients with structural heart disease remains suboptimal.2 While some VT recurrence may be due to inaccessible substrate or progression of cardiomyopathy, the high rate of failure underscores the importance of further refining methods to better identify arrhythmogenic substrates at the time of catheter ablation.In this issue, Martin et al3 investigated the effect of wavefront of ventricular activation on the substrate mapping of VT in patients with ischemic scar using high-density mapping with the Rhythmia system (Boston Scientific, United States). In 22 patients (20 male; age, 62±8 years; left ventricular ejection fraction, 36±8%; mean infarct age, 16.1±7.9 years) arrhythmogenic substrate was identified during atrial pacing, right ventricular pacing, and left ventricular pacing at a cycle length of 600 ms. VT was inducible in 19 patients and characterized with activation mapping in 19 of 23 VTs (mean cycle length, 419±71 ms). Voltage and propagation maps during pacing were compared with activation maps during VT depicting the putative isthmus. The authors found that scar as determined by bipolar voltage criteria, regions of late activation, lines of conduction block, and sites of late abnormal ventricular activations were dependent on activation wavefront. Between different pacing sites, voltage maps demonstrated considerable variability, with an overlap of only 44.6±18.3%, consistent with previous reports.4 Atrial pacing was associated with larger overall scar area compared with both right ventricular and left ventricular pacing. When the paced wavefront of activation was more perpendicular to the isthmus of the induced VT, zones of late activation and lines of block tended to correlate better with the VT isthmus location during tachycardia (although only in 7/19 patients were both ends of the isthmus clearly visualized on a single pace-activation map), and late abnormal ventricular activations were present over a larger area. The procedures were relatively long as may be expected from obtaining multiple activation maps, 256±64 minutes with total radiofrequency ablation time 39±15 minutes. Overall, a relatively small number of VT circuits were characterized and activation mapping was predominantly used (corroborated with entrainment mapping in only 9/19 VTs, and VT were terminated by radiofrequency ablation at isthmus sites in 8 out of 19 VTs). Nonetheless, the results support the paradigm that regions of slow and uncoupled conduction as well as lines of functional block during sinus or paced rhythm may approximate the functional isthmus of VT arising from ischemic scar, dependent on scar location, and isthmus orientation.These results put into perspective once more the challenges of the substrate-based approach to VT ablation. It is known that bipolar and unipolar voltage as well as electrogram characteristics such as fractionation, split potentials, late potentials, are not invariant tissue characteristics but contingent on the method of recording (ie, electrode size, interelectrode distance, electrode contact and incident angle, and filter settings) and influenced by the functional activation of scar.5 The finding in this study that the isthmuses of relatively slower VTs might be visible on activation mapping during pacing suggests that regions of conduction block operative during tachycardia are similar to those in paced rhythm. It is possible that more rapid pacing might be required to unmask functional block for more rapid arrhythmias. Additionally, while it is clearer that more potentially arrhythmogenic substrate or even the critical isthmus may be uncovered by choosing a second site of ventricular pacing during substrate-based ablation, more study is required to determine the likely optimal pacing site based on scar location and suspected isthmus direction for this approach.In addition to anatomic barriers to conduction, regions of functional block within scar determine critical portions of the VT circuitry. Studies of ischemic VT in patients have observed decremental responses during entrainment and resetting, different resetting curve responses between right ventricular outflow and apical entrainment sites, and also poor sinus rhythm pace-maps observed at VT isthmus sites with concealed entrainment responses.6,7 High-density mapping of faster VTs in a postmyocardial infarction swine model suggest that functional block in this setting may lead to overestimation of VT isthmus length defined by entrainment.8 Other factors such as wall thickness,9 proximity to the His-Purkinje system,10 and fiber orientation11 may play a more important role in smaller scars. The question therefore remains whether the findings of this study in terms of visualization of the VT isthmus would extend to smaller ischemic scars, nonischemic or intramural scars, or during faster induced VTs because regions of functional block during VT may be further disparate from those present in sinus or paced rhythm.Nonetheless, in larger ischemic scars, as high-density mapping techniques with multielectrode catheters enable identification of a greater number of sites with abnormal electrograms and late conduction, there is an increasing need to determine in an efficient manner sites, where ablation should be performed to interrupt putative VT circuits. Combining these activation mapping techniques with methods to subselect sites for ablation based on functional testing may be desirable, such as pace-mapping to identify channels of conduction,12–14 or using ventricular extrastimuli to dissociate local and near field components of abnormal electrograms.15,16 The integration of scar imaging with increasing granularity in assessment of composition, wall thickness, viability, myofiber orientation, together with these electrophysiological properties of scar should not only enable an improved understanding of which regions of scar is likely to harbor VT circuits, but also where these circuits are most vulnerable and accessible to catheter ablation. A challenge for future studies of substrate-based ablation includes the standardization of mapping tools, electrogram recording, pacing site relative to scar location, to facilitate a multimodality approach to elucidating VT circuitry, as well as compare and validate various substrate mapping techniques.DisclosuresDr Tedrow has received honoraria in the minor range from Biosense Webster, Abbott Medical, Boston Scientific, and Medtronic.FootnotesThe opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.Usha Tedrow, MD, MSc, Cardiovascular Division, Brigham and Women's Hospital, 75 Francis St, Boston, MA 02115. Email [email protected]harvard.eduReferences1. de Bakker JM, van Capelle FJ, Janse MJ, Tasseron S, Vermeulen JT, de Jonge N, Lahpor JR. Slow conduction in the infarcted human heart. 'Zigzag' course of activation.Circulation. 1993; 88:915–926.CrossrefMedlineGoogle Scholar2. Kumar S, Romero J, Mehta NK, Fujii A, Kapur S, Baldinger SH, Barbhaiya CR, Koplan BA, John RM, Epstein LM, Michaud GF, Tedrow UB, Stevenson WG. Long-term outcomes after catheter ablation of ventricular tachycardia in patients with and without structural heart disease.Heart Rhythm. 2016; 13:1957–1963. doi: 10.1016/j.hrthm.2016.07.001CrossrefMedlineGoogle Scholar3. Martin CA, Martin R, Maury P, Meyer C, Wong T, Dallet C, Shi R, Gajendragadkar P, Takigawa M, Frontera A, Cheniti G, Thompson N, Kitamura T, Vlachos K, Wolf M, Bourier F, Lam A, Duchâteau J, Massoullié G, Pambrun T, Denis A, Derval N, Dubois R, Hocini M, Haïssaguerre M, Jaïs P, Sacher F. Effect of activation wavefront on electrogram characteristics during ventricular tachycardia ablation.Circ Arrhythm Electrophysiol. 2019; 12:e007293. doi: 10.1161/CIRCEP.119.007293LinkGoogle Scholar4. Josephson ME, Anter E. Substrate mapping for ventricular tachycardia: assumptions and misconceptions.JACC Clin Electrophysiol. 2015; 1:341–352. doi: 10.1016/j.jacep.2015.09.001CrossrefMedlineGoogle Scholar5. Tung R, Josephson Mark E, Bradfield Jason S, Shivkumar K. Directional influences of ventricular activation on myocardial scar characterization.Circ Arrhythm Electrophysiol. 2016; 9:e004155.LinkGoogle Scholar6. Stevenson WG, Sager PT, Natterson PD, Saxon LA, Middlekauff HR, Wiener I. Relation of pace mapping QRS configuration and conduction delay to ventricular tachycardia reentry circuits in human infarct scars.J Am Coll Cardiol. 1995; 26:481–488.CrossrefMedlineGoogle Scholar7. Callans DJ, Zardini M, Gottlieb CD, Josephson ME. The variable contribution of functional and anatomic barriers in human ventricular tachycardia: an analysis with resetting from two sites.J Am Coll Cardiol. 1996; 27:1106–1111. doi: 10.1016/0735-1097(95)00585-4CrossrefMedlineGoogle Scholar8. Anter E, Tschabrunn CM, Buxton AE, Josephson ME. High-resolution mapping of postinfarction reentrant ventricular tachycardia: electrophysiological characterization of the circuit.Circulation. 2016; 134:314–327. doi: 10.1161/CIRCULATIONAHA.116.021955LinkGoogle Scholar9. Ciaccio EJ, Coromilas J, Wit AL, Peters NS, Garan H. Source-sink mismatch causing functional conduction block in re-entrant ventricular tachycardia.JACC Clin Electrophysiol. 2018; 4:1–16. doi: 10.1016/j.jacep.2017.08.019CrossrefMedlineGoogle Scholar10. Bogun F, Good E, Reich S, Elmouchi D, Igic P, Tschopp D, Dey S, Wimmer A, Jongnarangsin K, Oral H, Chugh A, Pelosi F, Morady F. Role of Purkinje fibers in post-infarction ventricular tachycardia.J Am Coll Cardiol. 2006; 48:2500–2507. doi: 10.1016/j.jacc.2006.07.062CrossrefMedlineGoogle Scholar11. Dillon SM, Allessie MA, Ursell PC, Wit AL. Influences of anisotropic tissue structure on reentrant circuits in the epicardial border zone of subacute canine infarcts.Circ Res. 1988; 63:182–206.LinkGoogle Scholar12. Brunckhorst CB, Delacretaz E, Soejima K, Maisel WH, Friedman PL, Stevenson WG. Identification of the ventricular tachycardia isthmus after infarction by pace mapping.Circulation. 2004; 110:652–659. doi: 10.1161/01.CIR.0000138107.11518.AFLinkGoogle Scholar13. de Chillou C, Groben L, Magnin-Poull I, Andronache M, MagdiAbbas M, Zhang N, Abdelaal A, Ammar S, Sellal JM, Schwartz J, Brembilla-Perrot B, Aliot E, Marchlinski FE. Localizing the critical isthmus of postinfarct ventricular tachycardia: the value of pace-mapping during sinus rhythm.Heart Rhythm. 2014; 11:175–181. doi: 10.1016/j.hrthm.2013.10.042CrossrefMedlineGoogle Scholar14. Tung R, Mathuria N, Michowitz Y, Yu R, Buch E, Bradfield J, Mandapati R, Wiener I, Boyle N, Shivkumar K. Functional pace-mapping responses for identification of targets for catheter ablation of scar-mediated ventricular tachycardia.Circ Arrhythm Electrophysiol. 2012; 5:264–272. doi: 10.1161/CIRCEP.111.967976LinkGoogle Scholar15. de Riva M, Naruse Y, Ebert M, Androulakis AFA, Tao Q, Watanabe M, Wijnmaalen AP, Venlet J, Brouwer C, Trines SA, Schalij MJ, Zeppenfeld K. Targeting the hidden substrate unmasked by right ventricular extrastimulation improves ventricular tachycardia ablation outcome after myocardial infarction.JACC Clin Electrophysiol. 2018; 4:316–327. doi: 10.1016/j.jacep.2018.01.013CrossrefMedlineGoogle Scholar16. Porta-Sánchez A, Jackson N, Lukac P, Kristiansen SB, Nielsen JM, Gizurarson S, Massé S, Labos C, Viswanathan K, King B, Ha ACT, Downar E, Nanthakumar K. Multicenter study of ischemic ventricular tachycardia ablation With Decrement-Evoked Potential (DEEP) mapping with extra stimulus.JACC Clin Electrophysiol. 2018; 4:307–315. doi: 10.1016/j.jacep.2017.12.005CrossrefMedlineGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsRelated articlesEffect of Activation Wavefront on Electrogram Characteristics During Ventricular Tachycardia AblationClaire A. Martin, et al. Circulation: Arrhythmia and Electrophysiology. 2019;12 June 2019Vol 12, Issue 6 Advertisement Article InformationMetrics © 2019 American Heart Association, Inc.https://doi.org/10.1161/CIRCEP.119.007457PMID: 31122053 Originally publishedMay 24, 2019 Keywordsfibroblastsmyocardial infarctioncollagencatheter ablationEditorialsgap junctionsPDF download Advertisement SubjectsArrhythmiasElectrophysiology
No takes yet. Share an insight, caveat, or question.
Qian et al. (2019) conducted an editorial in Ischemic scar and ventricular tachycardia (n=22). Varying activation wavefronts (atrial, right ventricular, and left ventricular pacing) vs. Comparison between different pacing sites was evaluated on Overlap of voltage maps between different pacing sites. Varying the activation wavefront during pacing revealed that scar characteristics are dependent on the wavefront, with only 44.6% overlap in voltage maps between different pacing sites.
Synapse has enriched 10 related papers. Consider them for comparative context: