Key result
RAPID mode third-generation laser balloon ablation provided fast, gapless lesion formation with thermal stacking and moderate tissue temperature rise in an experimental model.
Why the study?
The lesion formation properties of a motorized rotational delivery mode third-generation laser balloon compared to point-by-point laser ablation in patients with AF remain unclear.
Does RAPID mode LB3 ablation improve lesion formation compared to point-by-point ablation in a preclinical chicken muscle model?
Does RAPID mode LB3 ablation improve lesion formation compared to point-by-point ablation in a preclinical chicken muscle model?
In a preclinical model, RAPID mode third-generation laser balloon ablation demonstrates effective, gapless lesion formation with moderate temperature rise compared to point-by-point ablation.
Answers are grounded in this paper and cite their sources.
Ex vivo LB3 RAPID mode yields gapless lesions with thermal stacking and lower peak temperatures; leaves open clinical translation for AF ablation.
Background: The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear. Objective: model. Methods: Chicken muscles were cauterized using LB3 in RAPID mode with 13 W and 15 W and 50% overlapped point-by-point fashion with 7 W/30 seconds, 8.5 W/20 seconds, 10 W/20 seconds, and 12 W/20 seconds. Lesion depth, width, and continuity were compared. Lesion continuity was classified by the visible gap degree categorized from 1 (perfect) to 3 (poor). Thermodynamics and maximum tissue temperatures were assessed under infrared thermographic monitoring. Fifteen and 5 lesions were evaluated per ablation protocol for measurement of lesion size and continuity and for thermographic assessment, respectively. Conclusion: RAPID mode LB3 ablation could provide fast, gapless, and acceptable lesion formation with thermal stacking and moderate tissue temperature rise.
No takes yet. Share an insight, caveat, or question.
Nagase et al. (2022) studied Atrial fibrillation. RAPID mode third-generation laser balloon (LB3) ablation vs. Point-by-point laser ablation was evaluated on Lesion depth, width, continuity, and thermodynamics (p=<.001). RAPID mode third-generation laser balloon ablation provided fast, gapless lesion formation with thermal stacking and moderate tissue temperature rise in an experimental model.
Synapse has enriched 10 related papers. Consider them for comparative context: