Key result
Angiography-based vessel fractional flow reserve (vFFR) demonstrated excellent discriminative power for detecting functionally significant coronary lesions (FFR ≤ 0.80) with an AUC of 0.87.
Why the study?
Angiography-based functional assessment has emerged as a novel approach to assess coronary physiology, but its agreement with invasive wire-based FFR and RFR required investigation.
Does angiography-based vFFR accurately correlate with invasive wire-based FFR and RFR in patients with intermediate coronary stenoses?
Observational (n=236)
Analysts blinded to FFR and RFR values
No
Does angiography-based vFFR accurately correlate with invasive wire-based FFR and RFR in patients with intermediate coronary stenoses?
Effect estimate: AUC 0.87 (95% CI 0.83-0.92)
Angiography-based vFFR demonstrates substantial agreement and excellent discriminative power compared to invasive wire-based FFR and RFR for assessing intermediate coronary stenoses.
May support wire-free functional assessment; leaves open prospective validation before clinical use.
Background: Angiography-based functional assessment of coronary stenoses emerges as a novel approach to assess coronary physiology. We sought to investigate the agreement between invasive coronary wire-based fractional flow reserve (FFR), resting full-cycle ratio (RFR), and angiography-based vessel FFR (vFFR) for the functional assessment of coronary stenoses in patients with coronary artery disease. Materials and Methods: Between Jan 01, 2018, and Dec 31, 2020, 298 patients with 385 intermediate lesions received invasive coronary wire-based functional assessment (FFR, RFR or both) at a single tertiary medical center. Coronary lesions involving ostium or left main artery were excluded. vFFR analysis was performed retrospectively based on aortic root pressure and two angiographic projections. Results: In total, 236 patients with 291 lesions were eligible for vFFR analysis. FFR and RFR were performed in 258 and 162 lesions, respectively. The mean FFR, RFR and vFFR value were 0.84 ± 0.08, 0.90 ± 0.09, and 0.83 ± 0.10. vFFR was significantly correlated with FFR ( r = 0.708, P < 0.001) and RFR ( r = 0.673, P < 0.001). The diagnostic performance of vFFR vs. FFR was accuracy 81.8%, sensitivity 77.4%, specificity 83.9%, positive predictive value 69.9%, and negative predictive value 88.5%. The discriminative power of vFFR for FFR ≤ 0.80 or RFR ≤ 0.89 was excellent. Area under the receiver operating characteristic curve (AUC) was 0.87 (95% CI:0.83–0.92) for FFR and 0.80 (95% CI:0.73–0.88) for RFR. Conclusion: Angiography-based vFFR has a substantial agreement with invasive wire-based FFR and RFR in patients with intermediate coronary stenoses. vFFR can be utilized to assess coronary physiology without a pressure wire in a post hoc manner.
No takes yet. Share an insight, caveat, or question.
Chang et al. (2021) conducted an observational in Coronary artery disease with intermediate coronary stenoses (n=236). Angiography-based vessel fractional flow reserve (vFFR) vs. Invasive wire-based fractional flow reserve (FFR) and resting full-cycle ratio (RFR) was evaluated on Discriminative power of vFFR for functionally significant coronary lesions (FFR ≤ 0.80) (AUC 0.87, 95% CI 0.83-0.92). Angiography-based vessel fractional flow reserve (vFFR) demonstrated excellent discriminative power for detecting functionally significant coronary lesions (FFR ≤ 0.80) with an AUC of 0.87.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: