Key result
An optimization framework applied to a heart model identified elastic parameters (C=313 Pa, bf=17.8, bt=7.1, bft=12A) to optimally match the end-diastolic pressure-volume relationship.
Why the study?
Computational models of heart biomechanics depend on constitutive law parameters that have a wide range of values in the literature.
The proposed optimization framework successfully identifies patient-specific constitutive law parameters for physiological simulation of heart biomechanics.
May refine Guccione parameters for cardiac simulations; leaves open clinical validation before use.
Over the last decades, computational models have been applied in in-silico simulations of the heart biomechanics. These models depend on input parameters. In particular, four parameters are needed for the constitutive law of Guccione et al., a model describing the stress-strain relation of the heart tissue. In the literature, we could find a wide range of values for these parameters. In this work, we propose an optimization framework which identifies the parameters of a constitutive law. This framework is based on experimental measurements conducted by Klotz et al.. They provide an end-diastolic pressure-volume relationship. We applied the proposed framework on one heart model and identified the following elastic parameters to optimally match the Klotz curve: C=313 Pa, b f =17.8, b t =7.1 and b ft =12A. In general, this approach allows to identify optimized parameters for a constitutive law, for a patient-specific heart geometry. The use of optimized parameters will lead to physiological simulation results of the heart biomechanics and is therefore an important step towards applying computational models in clinical practice.
No takes yet. Share an insight, caveat, or question.
Kovacheva et al. (2020) studied Heart biomechanics. Optimization framework for constitutive law parameters was evaluated on Identification of elastic parameters to optimally match the Klotz curve. An optimization framework applied to a heart model identified elastic parameters (C=313 Pa, bf=17.8, bt=7.1, bft=12A) to optimally match the end-diastolic pressure-volume relationship.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: