Key result
Compressive dressing after pacemaker or ICD implantation fails to reduce pocket hematomas versus no dressing.
Why the study?
It was unclear whether applying a compressive dressing for three hours after pacemaker or ICD implantation and replacement prevents bleeding, hematomas, and pain.
Does a compressive dressing applied for three hours prevent bleeding, hematomas, and pain in patients undergoing pacemaker or ICD implantation or replacement?
Does a compressive dressing applied for three hours prevent bleeding, hematomas, and pain in patients undergoing pacemaker or ICD implantation or replacement?
p-value: p=0.24
Routine use of a compressive dressing for three hours after pacemaker or ICD implantation does not significantly reduce bleeding, pocket hematomas, or pain in standard-risk patients.
Aim To investigate whether a compressive dressing after pacemaker or implantable cardioverter defibrillator (ICD) implantation and replacement applied for three hours can prevent bleeding, hematomas and pain. Method The study was a quasi-experimental interventional study including patients scheduled for implantation or replacement of a pacemaker or an ICD. In alternating months patients either received a compressive dressing (intervention group) or no compressive dressing (control group). Patients were followed at the catheterization lab, for three hours on the ward and until the first outpatient control visit (after 1-3 months). Outcomes was: Bleeding graded as bleeding, oozing or pocket-hematomas. Hematomas were measured by degrees and size. Pain was rated in a numerical rank scale (NRS). Results A total of 242 elective patients were included (intervention group n=114, control group n=128). The intervention group did not show any significant difference in development of pocket-hematomas compared to the control (p=0.24). Pain score was low in both groups (intervention NRS=1.41 vs. control NRS 1.32). Furthermore, no significant difference in pocket hematomas at follow-up were observed (p=0.77). Conclusion Using a compressive dressing did not significantly reduce bleeding or pocket hematomas after pacemaker or ICD implantation or replacement. Furthermore, no significant difference related to pain was observed. This study shows that patients who are not considered to be at elevated risk for bleeding or pocket-hematomas do not seem to benefit from a compressive dressing. Keywords Pacemaker, Implantable Cardioverter Defibrillator, Prophylactic compression bandaging, Pocket-hematoma, Device, Compression tool.
No takes yet. Share an insight, caveat, or question.
Fuglsbjerg et al. (2025) studied Pacemaker or ICD implantation or replacement (n=242). Compressive dressing vs. No compressive dressing was evaluated on Development of pocket-hematomas (p=0.24). A compressive dressing applied for three hours after pacemaker or ICD implantation did not significantly reduce the development of pocket-hematomas compared to no dressing (p=0.24).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: