Why the study?
What are the incidence and predictors of clinically significant pocket haematoma following ICD implantation?
What are the incidence and predictors of clinically significant pocket haematoma following ICD implantation?
Pocket haematoma after ICD implantation occurs in 2.2% of patients, is associated with a high risk of infection, and is predicted by heparin bridging, prior stroke, sub-pectoral placement, older age, and pacemaker upgrade.
Pocket haematoma after ICD implantation may raise infection risk; this cohort analysis leaves open targeted prevention strategies.
AIMS: Pocket haematoma is a common complication after defibrillator [implantable cardioverter defibrillator (ICD)] implantation, which is not only painful, but also increases the risk of device-related infection, and possibly embolic events. The present study seeks to evaluate the rate and predictors of clinically significant pocket haematoma. METHODS AND RESULTS: This study included 2500 patients receiving an ICD in the SIMPLE trial. A clinically significant pocket haematoma was defined as a haematoma that required re-operation or interruption of oral anticoagulation (OAC) therapy. Clinically significant pocket haematoma occurred in 56 of 2500 patients (2.2%) of which 6 (10.7%) developed device-related infection. Patients who developed pocket haematoma were older (mean age 67.6 ± 8.8 years vs. 62.7 ± 11.6 years, P < 0.001), were more likely to have permanent atrial fibrillation (30.4 vs. 6.7%, P < 0.001) and a history of stroke (17.9 vs. 6.7%, P = 0.004), or were more likely to receive peri-operative OAC (50.0 vs. 28.4%, P < 0.001), unfractionated heparin (16.1 vs. 5.2%, P = 0.003), or low-molecular-weight heparin (37.5 vs. 17.5%, P < 0.001). Independent predictors of wound haematoma on multivariable analysis included the use of heparin bridging (OR 2.65, 95% CI 1.48-4.73, P = 0.001), sub-pectoral location of ICD (OR 2.00, 95% CI 1.12-3.57, P =0.020), previous stroke (OR 2.47, 95% CI 1.20-5.10, P = 0.015), an upgrade from permanent pacemaker (OR 2.52, 95% CI 1.07-5.94, P = 0.035), and older age (OR 1.03, 95% CI 1.00-1.06, P = 0.049). CONCLUSION: Pocket haematoma remains an important complication of ICD implantation and is associated with a high risk of infection. Independent predictors of pocket haematoma include heparin bridging, prior stroke, sub-pectoral placement of ICD, older age, and upgrade from a pacemaker.
No takes yet. Share an insight, caveat, or question.
Masiero et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: