Key result
Routine ICD implantation significantly reduced all-cause mortality in patients with nonischemic cardiomyopathy (RR 0.74; 95% CI 0.56-0.97; P=0.03), driven by a reduction in sudden cardiac death.
Why the study?
Does implantable cardioverter defibrillator (ICD) implantation reduce mortality in patients with nonischemic cardiomyopathy for primary prevention?
Meta-Analysis
Does implantable cardioverter defibrillator (ICD) implantation reduce mortality in patients with nonischemic cardiomyopathy for primary prevention?
Relative Risk: 0.74 (95% CI 0.56–0.97)
p-value: p=.03
In patients with nonischemic cardiomyopathy, ICD implantation for primary prevention significantly reduces all-cause mortality, driven by a reduction in sudden cardiac death.
The evidence to support implantable cardioverter defibrillator ( ICD ) in subjects with nonischemic cardiomyopathy ( NICM ) for primary prevention of sudden cardiac death ( SCD ) is not robust. This meta‐analysis intends to assess the impact of routine ICD implantation for primary prevention of mortality due to SCD in NICM based on all the published randomized clinical trials ( RCT s). Six RCT s were selected using PubMed/Medline, EMBASE , and CENTRAL from inception to December 2016. Outcomes were calculated as random‐effects relative risk ( RR ) and risk difference ( RD ) with 95% confidence interval ( CI ). Patients were randomized to ICD arm and control arm (usual care, medical treatment, and anti‐arrhythmic drugs). ICD significantly reduced all‐cause mortality in NICM patients ( RR , 0.74, 95% CI , 0.56‐0.97, P = .03, I 2 = 40). Mortality benefit was achieved due to a significant reduction in sudden cardiac death ( SCD ) ( RR , 0.47, 95% CI , 0.30‐0.73, P < .001, I 2 = 0). There were no statistical differences between two groups with regard to risk of noncardiac mortality, non‐ SCD , cardiac arrest, cardiac transplant, sustained ventricular tachycardia ( VT ), and VT requiring medical treatment. Our results support efficacy of ICD s at reducing all‐cause mortality due to a reduction in SCD .
No takes yet. Share an insight, caveat, or question.
Khan et al. (2017) conducted a meta-analysis in nonischemic cardiomyopathy. Implantable cardioverter defibrillator (ICD) vs. usual care, medical treatment, and anti-arrhythmic drugs was evaluated on all-cause mortality (RR 0.74, 95% CI 0.56-0.97, p=.03). Routine ICD implantation significantly reduced all-cause mortality in patients with nonischemic cardiomyopathy (RR 0.74; 95% CI 0.56-0.97; P=0.03), driven by a reduction in sudden cardiac death.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: