Key result
Implantable cardioverter defibrillators were associated with a significant mortality benefit in patients with non-ischemic cardiomyopathy (OR 0.76; 95% CI 0.64-0.91).
Why the study?
Does an implantable cardioverter defibrillator (ICD) reduce mortality in patients with non-ischemic cardiomyopathy for primary prevention?
Meta-Analysis
Does an implantable cardioverter defibrillator (ICD) reduce mortality in patients with non-ischemic cardiomyopathy for primary prevention?
Odds Ratio: 0.76 (95% CI 0.64–0.91)
ICDs provide a mortality benefit for primary prevention in non-ischemic cardiomyopathy, though this benefit may be attenuated in patients on optimal guideline-directed medical therapy.
Supports ICD consideration for primary prevention in NICM; confirms mortality benefit across pooled studies.
ICD in Nonischemic Cardiomyopathy Introduction Implantation of an implantable cardioverter defibrillator (ICD) for primary prevention of sudden cardiac death (SCD) is controversial in view of the recent DANISH trial which suggested no benefit with ICD for primary prevention in patients with non‐ischemic cardiomyopathy (NICMP). Methods We conducted a meta‐analysis of randomized control trials studying the role of ICD in primary prevention of SCD in patients with NICMP. Only six studies were identified after the application of inclusion/exclusion criteria. Results Pooling of these randomized trials showed a statistically significant benefit of using ICDs in patients with NICMP [OR 0.76 (0.64 – 0.91), I2 = 0%]. Sensitivity analysis did not show a statistically significant mortality benefit of ICD in NICMP in trials which had adequate beta blocker, ACE/ARB and aldosterone receptor blocker (ALD‐RB) use [OR 0.70 (0.41, 1.19), I2 = 70%]. Conclusion The DANISH trial's failure to show mortality benefit may be due to the significant number of patients who had CRT. Our meta‐analysis studied the independent effect of ICDs and showed them to be associated with net mortality benefits in patients who are not on optimal guideline directed medical therapy; especially the patients not on ALD‐RB.
No takes yet. Share an insight, caveat, or question.
Luni et al. (2017) conducted a meta-analysis in Non-ischemic cardiomyopathy (NICMP). Implantable cardioverter defibrillator (ICD) vs. Control (no ICD) was evaluated on Mortality (OR 0.76, 95% CI 0.64-0.91). Implantable cardioverter defibrillators were associated with a significant mortality benefit in patients with non-ischemic cardiomyopathy (OR 0.76; 95% CI 0.64-0.91).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: