Key result
Higher aortic valve calcium mass was associated with paravalvular regurgitation after TAVI, and PR location correlated with the cusp having the highest AVC.
Why the study?
Does the severity and location of aortic valve calcification predict the occurrence and location of paravalvular regurgitation after TAVI?
Observational (n=56)
Does the severity and location of aortic valve calcification predict the occurrence and location of paravalvular regurgitation after TAVI?
Greater aortic valve calcium mass and its specific cusp location on preoperative CT predict the occurrence and location of paravalvular regurgitation after TAVI.
Answers are grounded in this paper and cite their sources.
May link AVC distribution to PR location after TAVI; leaves open whether calcium mapping refines positioning in prospective studies.
OBJECTIVES: To determine whether the location of aortic valve calcium (AVC) influences the location of paravalvular regurgitation (PR). PR is an adverse effect of transcatheter aortic valve implantation (TAVI) with a negative effect on long-term patient survival. The relationship between AVC and the occurrence of PR has been documented. However, the relationship between the distribution of AVC and the location of PR is still sparsely studied. The purpose of this study was to correlate severity and location of AVC with PR in patients treated with TAVI. METHODS: Fifty-six consecutive patients who underwent transaortic or transapical TAVI and had preoperative computed tomography scans were included in this retrospective study. The volume, mass and location of AVC was determined and compared between patients with and without PR using a non-parametric t-test. Postoperative echocardiography was performed to determine the presence and location of PR, which was associated with the cusp with highest AVC using a χ(2) test. RESULTS: Valve deployment was successful in all 56 patients. PR was present in 38 patients (68%) after TAVI. There was a non-significantly higher volume of AVC in the PR group [214 (70-418) vs 371 (254-606) cm(3), P = 0.15]. AVC mass was significantly higher in patients with PR than in patients without PR [282 (188-421) vs 142 (48-259) mg, respectively, P = 0.043]. The location of PR was determined in 36 of these patients. Of these 36 patients, PR occurred at the cusp with the highest AVC in 20 patients (56%, χ(2) P = 0.030). CONCLUSIONS: In our population, PR was associated with greater AVC mass. Moreover, the location of PR was associated with the cusp with the highest amount of AVC.
No takes yet. Share an insight, caveat, or question.
Koh et al. (2014) conducted an observational in Paravalvular regurgitation after transcatheter aortic valve implantation (n=56). Aortic valve calcium (AVC) mass and location vs. Lower AVC mass / different location was evaluated on Presence and location of paravalvular regurgitation (PR) (p=0.043). Higher aortic valve calcium mass was associated with paravalvular regurgitation after TAVI, and PR location correlated with the cusp having the highest AVC.
Synapse has enriched 10 related papers. Consider them for comparative context: