Key result
Hydrops, skin edema, and mild or greater mitral regurgitation were associated with fetal or postnatal demise in primary fetal cardiomyopathy.
Observational (n=18)
In primary fetal cardiomyopathy, hydrops and atrioventricular valvar regurgitation are associated with poor outcomes, whereas Tei indices have limited predictive value.
Answers are grounded in this paper and cite their sources.
May inform fetal counseling in rare cardiomyopathy; extends limited observational data but leaves open prospective validation.
OBJECTIVES: Primary fetal cardiomyopathy is a rare entity, with a poor prognosis. We sought to describe its echocardiographic characteristics and outcomes. METHODS: We performed a 12-year retrospective review of fetuses with primary cardiomyopathy. RESULTS: Of more than 6000 fetuses evaluated, 25 met criteria for primary cardiomyopathy, and 18 had sufficient echocardiographic and pregnancy outcome data for inclusion. At echocardiography, the median gestational age was 29.6 weeks (range, 21.0-36.4 weeks); median cardiovascular profile score was 6 (range, 1-9); median right ventricular Tei index was 0.52 (range, 0.32-0.94); and median left ventricular Tei index was 0.40 (range, 0.15-0.88). Two had fetal demise, and 16 survived to delivery. The median cardiovascular profile score in those with fetal demise was 3.0 and in those who survived to delivery was 6.5 (range, 3-9; P = .14). The median right ventricular Tei index in those with fetal demise was 0.39 and in those surviving to delivery was 0.53 (range, 0.38-0.94; P = .49). The median left ventricular Tei index in those with fetal demise was 0.29 and in those surviving to delivery was 0.42 (range, 0.15-0.88; P = .50). Sixty-day survival was available in 11 of 16 fetuses. In addition to the 2 with fetal demise, 4 had postnatal demise, and 5 were alive at a median follow-up of 39 months. Hydrops (P = .01), skin edema (P = .01), and mild or greater mitral regurgitation (P = .02) were associated with fetal or postnatal demise, with a trend toward an association between moderate or greater tricuspid regurgitation (P = .07) and fetal or postnatal demise. CONCLUSIONS: Hydrops and atrioventricular valvar regurgitation are ominous signs in primary fetal cardiomyopathy. Although other commonly used methods for assessing cardiovascular performance may help in diagnosing primary cardiomyopathy, these data suggest limited predictive value.
No takes yet. Share an insight, caveat, or question.
Ezon et al. (2016) conducted an observational in Primary fetal cardiomyopathy (n=18). Hydrops, skin edema, and atrioventricular valvar regurgitation vs. Absence of these signs was evaluated on Fetal or postnatal demise (p=0.01). Hydrops, skin edema, and mild or greater mitral regurgitation were associated with fetal or postnatal demise in primary fetal cardiomyopathy.
Synapse has enriched 10 related papers. Consider them for comparative context: