Key result
In patients with moderate to severe aortic regurgitation, systolic backward flow ≥21 ml identified marked systolic flow displacement with a positive likelihood ratio of 6.0.
Why the study?
Can conventional phase-contrast velocity MRI detect and quantify flow displacement in the ascending aorta in patients with aortic regurgitation?
Cross-Sectional (n=62)
No
Can conventional phase-contrast velocity MRI detect and quantify flow displacement in the ascending aorta in patients with aortic regurgitation?
Answers are grounded in this paper and cite their sources.
Conventional phase-contrast MRI flow rate curves can effectively detect and quantify flow displacement in the ascending aorta of patients with aortic regurgitation, suggesting its utility as a screening tool.
Ascending aorta (AA) flow displacement (FD) is a surrogate for increased wall shear stress. We prospectively studied the flow profile in the AA in patients with aortic regurgitation (AR), to identify predictors of FD and investigate whether magnetic resonance imaging (MRI) phase-contrast flow rate curves (PC-FRC) contain quantitative information related to FD. Forty patients with chronic moderate (n = 14) or severe (n = 26) AR (21 (53%) with bicuspid aortic valve) and 22 controls were investigated. FD was determined from phase-contrast velocity profiles and defined as the distance between the center of the lumen and the "center of velocity" of the peak systolic forward flow or the peak diastolic negative flow, normalized to the lumen radius. Forward and backward volume flow was determined separately for systole and diastole. Seventy percent had systolic backward flow and 45% had diastolic forward flow in large areas of the vessel. AA dimension was an independent predictor of systolic FD while AA dimension and regurgitant volume were independent predictors of diastolic FD. Valve phenotype was not an independent predictor of systolic or diastolic FD. The linear relationships between systolic backward flow and systolic FD and diastolic forward flow and diastolic FD were strong (R = 0.77 and R = 0.76 respectively). Systolic backward flow and diastolic forward flow identified marked systolic and diastolic FD (≥0.35) with a positive likelihood ratio of 6.0 and 10.8, respectively. In conclusion, conventional PC-FRC data can detect and quantify FD in patients with AR suggesting the curves as a research and screening tool in larger patient populations.
No takes yet. Share an insight, caveat, or question.
Bech‐Hanssen et al. (2017) conducted a cross-sectional in Aortic regurgitation (n=62). Moderate to severe aortic regurgitation vs. Healthy controls was evaluated on Detection of marked systolic flow displacement (≥0.35) using systolic backward flow ≥21 ml (PLR 6.0, 95% CI 2.1-17.1). In patients with moderate to severe aortic regurgitation, systolic backward flow ≥21 ml identified marked systolic flow displacement with a positive likelihood ratio of 6.0.
Synapse has enriched 10 related papers. Consider them for comparative context: