Key result
Aortic root distortion or insufficiency was noted in 33% (6/18) of patients during RVOT balloon angioplasty, with no progression of aortic insufficiency observed post-TPV implantation.
Why the study?
Does RVOT balloon angioplasty prior to TPV implantation cause significant aortic root distortion or aortic insufficiency?
Observational (n=118)
Does RVOT balloon angioplasty prior to TPV implantation cause significant aortic root distortion or aortic insufficiency?
Answers are grounded in this paper and cite their sources.
Aortic root distortion and aortic insufficiency are common during RVOT balloon angioplasty prior to TPV implantation but appear benign in most cases, though careful evaluation is needed in certain anatomic subtypes.
OBJECTIVE: To describe the significance of aortic root distortion (AD) and/or aortic valve insufficiency (AI) during balloon angioplasty of the right ventricular outflow tract (RVOT) performed to rule out coronary artery compression prior to transcatheter pulmonary valve (TPV) implantation. METHODS: AD/AI was assessed by retrospective review of all procedural aortographies performed to evaluate coronary anatomy prior to TPV implantation. AD/AI was also reviewed in all pre-post MPV implant echocardiograms to assess for progression. RESULTS: From 04/2007 to 3/2015, 118 pts underwent catheterization with intent for TPV implant. Mean age and weight were 24.5 ± 12 years and 64.3 ± 20 kg, respectively. Diagnoses were: TOF (53%), D-TGA/DORV (18%), s/p Ross (15%), and Truncus (9%). Types of RV-PA connections were: conduits (96), bioprosthetic valves (14), and other (7). Successful TPV implant occurred in 91 pts (77%). RVOT balloon angioplasty was performed in 43/118 pts (36%). Aortography was performed in 18/43 pts with AD/AI noted in 6/18 (33%); 2 with D-TGA (1 s/p Lecompte, 1 s/p Rastelli), 2 with TOF, 1 Truncus and 1 s/p Ross. Procedure was aborted in the 2 who developed severe AD/AI. TPV was implanted in 3/4 patients with mild AD/AI. Review of pre-post TPV implantation echocardiograms in 83/91 pts (91%) revealed no new/worsened AI in any patient. CONCLUSION: AD/AI is relatively common on aortography during simultaneous RVOT balloon angioplasty. Lack of AI progression by echocardiography post-TPV implant suggests these may be benign findings in most cases. However, AD/AI should be carefully evaluated in certain anatomic subtypes with close RVOT/aortic alignments.
No takes yet. Share an insight, caveat, or question.
Torres et al. (2016) conducted an observational in Transcatheter pulmonary valve replacement candidates (n=118). Balloon angioplasty of the right ventricular outflow tract was evaluated on Aortic root distortion (AD) and/or aortic valve insufficiency (AI). Aortic root distortion or insufficiency was noted in 33% (6/18) of patients during RVOT balloon angioplasty, with no progression of aortic insufficiency observed post-TPV implantation.
Synapse has enriched 10 related papers. Consider them for comparative context: