Key result
Achieving a force time integral above 543.0gs during radiofrequency catheter ablation reduced procedural time and fluoroscopy time.
Why the study?
Does direct contact force measurement affect procedural and fluoroscopy times during radiofrequency catheter ablation for paroxysmal atrial fibrillation?
Observational (n=95)
Yes
Does direct contact force measurement affect procedural and fluoroscopy times during radiofrequency catheter ablation for paroxysmal atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Higher contact force and force-time integral during radiofrequency catheter ablation for pulmonary vein isolation are associated with significantly shorter procedural and fluoroscopy times without increasing complications.
AIMS: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicentre prospective study, we assessed the effect of direct contact force (CF) measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). METHODS AND RESULTS: A new open-irrigated tip catheter with CF sensing (SmartTouch™, Biosense Webster Inc.) was used. All the patients underwent the first ablation procedure for paroxysmal AF with antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. Ninety-five patients were enroled in nine centres and successfully underwent ablation. Overall procedure time, fluoroscopy time, and ablation time were 138.0 ± 67.0, 14.3 ± 11.2, and 33.8 ± 19.4 min, respectively. The mean CF value during ablation was 12.2 ± 3.9 g. Force time integral (FTI) analysis showed that patients achieving a value below the median of 543.0gs required longer procedural (158.0 ± 74.0 vs. 117.0 ± 52.0 min, P = 0.004) and fluoroscopy (17.5 ± 13.0 vs. 11.0 ± 7.7 min, P = 0.007) times as compared with those in whom FTI was above this value. Patients in whom the mean CF during ablation was >20 g required shorter procedural time (92.0 ± 23.0 vs. 160.0 ± 67.0 min, P = 0.01) as compared with patients in whom this value was <10 g. Four groin haematomas were the only complications observed. CONCLUSION: Contact force during RFCA for PV isolation affects procedural parameters, in particular procedural and fluoroscopy times, without increasing complications.
No takes yet. Share an insight, caveat, or question.
Stabile et al. (2013) conducted an observational in Paroxysmal atrial fibrillation (n=95). Force time integral (FTI) above the median of 543.0gs during ablation vs. FTI below the median of 543.0gs was evaluated on Procedural time (minutes) (p=0.004). Achieving a force time integral above 543.0gs during radiofrequency catheter ablation reduced procedural time and fluoroscopy time.