Key result
Radiofrequency catheter ablation with contact force measurement reduced ablation time compared to a standard catheter.
Why the study?
Does direct catheter force measurement reduce ablation time and procedure duration in patients with paroxysmal atrial fibrillation undergoing pulmonary vein isolation?
Does direct catheter force measurement reduce ablation time and procedure duration in patients with paroxysmal atrial fibrillation undergoing pulmonary vein isolation?
The use of contact force sensing technology during radiofrequency catheter ablation for paroxysmal atrial fibrillation significantly reduces ablation time, total procedure duration, and total energy delivered compared to standard catheters.
Answers are grounded in this paper and cite their sources.
Contact force sensing was associated with shorter ablation times; extends observational data but leaves open randomized confirmation of outcomes.
BACKGROUND: Electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). OBJECTIVE: We assessed the impact of direct catheter force measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). METHODS: Fifty consecutive patients (28 male) with paroxysmal AF who underwent their first procedure of circumferential pulmonary vein (PV) isolation (PVI) were assigned to either RFCA using (1) a standard 3.5-mm open-irrigated-tip catheter or (2) a catheter with contact force measurement capabilities. Using the endpoint of PVI with entry and exit block, acute procedural parameters were assessed. RESULTS: Procedural data showed a remarkable decline in ablation time (radiofrequency time needed for PVI) from 50.5 ± 15.9 to 39.0 ± 11.0 minutes (P = 0.007) with a reduction in overall procedure duration from 185 ± 46 to 154 ± 39 minutes (P = 0.022). In parallel, the total energy delivered could be significantly reduced from 70,926 ± 19,470 to 58,511 ± 14,655 Ws (P = 0.019). The number of acute PV reconnections declined from 36% to 12% (P = 0.095). CONCLUSIONS: The use of contact force sensing technology is able to significantly reduce ablation and procedure times in PVI. In addition, energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Procedural efficacy and safety of this new feature have to be evaluated in larger cohorts.
No takes yet. Share an insight, caveat, or question.
Martinek et al. (2012) studied Paroxysmal atrial fibrillation (n=50). Radiofrequency catheter ablation with contact force measurement vs. Standard 3.5-mm open-irrigated-tip catheter was evaluated on Ablation time (radiofrequency time needed for pulmonary vein isolation) (p=0.007). Radiofrequency catheter ablation with contact force measurement reduced ablation time compared to a standard catheter.