Key result
Direct catheter force measurement during radiofrequency ablation reduced ablation time and overall procedure time.
Why the study?
Does direct catheter force measurement reduce procedure time and improve outcomes in patients undergoing radiofrequency catheter ablation for paroxysmal and persistent atrial fibrillation?
Cohort (n=198)
Does direct catheter force measurement reduce procedure time and improve outcomes in patients undergoing radiofrequency catheter ablation for paroxysmal and persistent atrial fibrillation?
The use of contact force sensing technology during radiofrequency catheter ablation for atrial fibrillation significantly reduces ablation, procedure, and fluoroscopy times while maintaining safety.
Answers are grounded in this paper and cite their sources.
May shorten AF ablation times; leaves open outcome benefits and need for randomized confirmation before practice change.
BACKGROUND: Sufficient electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). OBJECTIVE: We assessed the impact of direct catheter force measurement on acute procedural parameters and outcome of RFCA for paroxysmal and persistent atrial fibrillation (AF). METHODS: Ninety-nine consecutive patients (70% men) with paroxysmal (63.6%) or persistent AF underwent left atrial RFCA using a 3.5-mm open-irrigated-tip (OIT) catheter with contact force measurement capabilities (group 1). For comparison a case-matched cohort with standard OIT catheters was used (99 patients; group 2). Case matching included gender, type of AF, number or RFCA procedures, and type of procedure. RESULTS: Procedural data showed a significant decline in radiofrequency ablation time from 52 ± 20 to 44 ± 16 minutes (P = 0.003) with a remarkable mean reduction in overall procedure time of 34 minutes (P = 0.0001; 225.8 ± 53.1 vs 191.9 ± 53.3 minutes). In parallel, the total fluoroscopy time could be significantly reduced from 28.5 ± 11.0 to 19.9 ± 9.3 minutes (P = 0.0001) as well as fluoroscopy dose from 74.1 ± 58.0 to 56.7 ± 38.9 Gy/cm(2) (P = 0.016). Periprocedural complications were similar in both groups. CONCLUSIONS: The use of contact force sensing technology is able to significantly reduce ablation, procedure, and fluoroscopy times as well as dose in RFCA of AF in a mixed case-matched group of paroxysmal and persistent AF. Energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Additionally 12-month outcome data showed increased efficacy. Such time saving and equally safe technology may have a relevant impact on laboratory management and increased cost effectiveness.
No takes yet. Share an insight, caveat, or question.
Sigmund et al. (2014) conducted a cohort in Paroxysmal and persistent atrial fibrillation (n=198). Radiofrequency catheter ablation with direct catheter force measurement vs. Standard open-irrigated-tip catheters was evaluated on Radiofrequency ablation time (p=0.003). Direct catheter force measurement during radiofrequency ablation reduced ablation time and overall procedure time.
Synapse has enriched 10 related papers. Consider them for comparative context: