Key result
Frontal-lead isolated very low QRS voltage predicts positive tilt-table testing with ~0.81 AUC.
Why the study?
The cause of syncope is generally determined by clinical manifestations, with little discussion regarding the value of electrocardiograms for diagnosing neurally mediated syncope.
Does isolated very low QRS voltage on baseline ECG predict a positive tilt-table test response in patients with suspected neurally mediated syncope?
Cohort (n=399)
Electrocardiologists blinded to tilt-table testing results
No
Does isolated very low QRS voltage on baseline ECG predict a positive tilt-table test response in patients with suspected neurally mediated syncope?
Effect estimate: AUC 0.806 (95% CI 0.764-0.844)
p-value: p=<0.0001
Isolated very low QRS voltage in the frontal leads is a non-invasive, accessible baseline ECG marker that independently and robustly predicts a positive tilt-table test response in patients with suspected neurally mediated syncope.
Objective: The cause of syncope is generally determined based on clinical manifestations. There has been little discussion about the value of electrocardiograms for diagnosing neurally mediated syncope. The aim of this study was to test the predictive value of the isolated very low QRS voltage in tilt-table testing for suspected neurally mediated syncope in a Chinese population. Methods: This retrospective study enrolled patients with suspected neurally mediated syncope. Tilt-table testing was a part of the diagnostic examination. Each patient underwent echocardiography and electrocardiogram. isolated very low QRS voltage referred to a voltage of ⩽0.3 mV for the QRS complex in an isolated frontal lead or ⩽0.7 mV for the QRS complex in an isolated precordial lead. Results: In total, 157 patients were included in the tilt-table testing positive group, and 242 patients were included in the tilt-table testing negative group. Compared with the testing negative group, the testing positive group had more patients with isolated very low QRS voltage in the frontal leads ( p < 0.001). Moreover, for patients with isolated very low QRS voltage in the precordial leads, no significant difference was noted between the testing positive group and testing negative group ( p = 0.289). Isolated very low QRS voltage in the frontal leads demonstrated 84.08% sensitivity and 74.38% specificity for a positive tilt-table testing response. The area under the curve of isolated very low QRS voltage for a positive tilt-table testing response in frontal leads was 0.806 ( p < 0.0001). Conclusion: In patients with suspected neurally mediated syncope, isolated very low QRS voltage in the frontal leads is a parameter that can predict a positive tilt-table testing response. The presence of isolated very low QRS voltage in frontal leads can serve as a parameter for evaluating syncope patients.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2024) conducted a cohort in Suspected neurally mediated syncope (n=399). Isolated very low QRS voltage in frontal leads vs. Absence of isolated very low QRS voltage in frontal leads was evaluated on Positive tilt-table testing response (AUC 0.806, 95% CI 0.764-0.844, p=<0.0001). In patients with suspected neurally mediated syncope, isolated very low QRS voltage in the frontal leads predicted a positive tilt-table testing response with an AUC of 0.806.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: