Answers are grounded in this paper and cite their sources.
Main insulation of windings connected with valves in high voltage direct current (HVDC) convert transformers withstands pulsating DC voltages. This paper presents breakdown properties of oil-impregnated paper under pulsating DC voltages at different temperatures. Progressive stress tests were carried out to obtain breakdown voltages of oil-impregnated paper with thickness of 0.2 mm under pulsating DC voltages at different temperatures. Constant stress tests were executed to measure time to breakdown of the oil-paper specimens. Both types of the experiments were also undertaken under either AC or DC voltages. An electrical aging lifetime model was proposed for the oil-impregnated paper, and parameters of the electrical aging lifetime model were presented. Experiments and analysis results show that the breakdown voltages and time to breakdown of oil-paper insulation are influenced by temperature significantly.
No takes yet. Share an insight, caveat, or question.
Li et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: