Key result
The Spacelab 90207 oscillometric monitor recorded systolic BP 6-12 mmHg higher and diastolic BP 1-2.6 mmHg higher than auscultatory readings during pregnancy.
Why the study?
How does oscillometric blood pressure monitoring compare to sphygmomanometric measurement regarding precision, consistency, and reproducibility in diabetic and non-diabetic pregnancy?
Observational (n=192)
How does oscillometric blood pressure monitoring compare to sphygmomanometric measurement regarding precision, consistency, and reproducibility in diabetic and non-diabetic pregnancy?
Oscillometric blood pressure readings are systematically higher than auscultatory readings during pregnancy, though repeated measurements can improve precision and reproducibility.
Oscillometric BP may differ from auscultatory readings in pregnancy; leaves open validation needs for diabetic monitoring.
A monitor (Spacelab 90207) was compared with sphygmomanometric blood pressure (BP) with respect to reproducibility and variations on precision and consistency. Some 133 women with type 1 diabetes mellitus and 59 non-diabetic women were recruited. During pregnancy, systolic BP was between 6 and 12 mmHg higher in the oscillometric than the auscultatory readings, and diastolic BP was between 1 and 2.6 mmHg. The association of difference with the mean BP disappeared with progression of pregnancy and the repetition of measurements in diabetic pregnancy. The precision, reproducibility, and trend of association over the scale of measurement were improved in the repeated compared to individual measurements, whereas consistency did not improve.
No takes yet. Share an insight, caveat, or question.
Lauszus et al. (2007) conducted an observational in Pregnancy (diabetic and non-diabetic) (n=192). Spacelab 90207 monitor (oscillometric) vs. Sphygmomanometric blood pressure (auscultatory) was evaluated on Reproducibility, precision, and consistency of blood pressure measurements. The Spacelab 90207 oscillometric monitor recorded systolic BP 6-12 mmHg higher and diastolic BP 1-2.6 mmHg higher than auscultatory readings during pregnancy.