UNICORN-assisted TAVR achieved 100% technical success and 93.3% procedural success in patients at high anatomic risk for coronary obstruction.
Observational (n=15)
No
Does the UNICORN technique prevent coronary obstruction in patients at high anatomic risk undergoing TAVR?
The UNICORN technique appears technically reproducible and safe for preventing coronary obstruction in high-risk patients undergoing TAVR.
Background: Coronary obstruction (CO) during transcatheter aortic valve replacement (TAVR) is associated with significant morbidity and mortality. UNICORN (Undermining Iatrogenic Coronary Obstruction with Radiofrequency Needle) is a novel technique designed to prevent CO by performing electrosurgical leaflet traversal followed by intraleaflet valve implantation or complete leaflet laceration accomplished using noncompliant balloons. However, its efficacy and safety are not well established. Methods: We retrospectively reviewed all patients who underwent UNICORN-assisted TAVR for both valve-in-valve and native valve procedures at a single high-volume center between September 2024 and September 2025. Patients were selected based on preprocedural cardiac computed tomography demonstrating high anatomic risk for CO. In all cases, the target leaflet was traversed using an electrified 0.014″ wire, followed by serial noncompliant balloon dilatations of the leaflet to either achieve complete leaflet laceration or to accommodate for intra-leaflet valve implantation. Balloon-expandable valves were used in all procedures. Results: Fifteen patients underwent UNICORN-assisted TAVR. Twelve were valve-in-valve cases, and 3 involved native valves. The right coronary cusp was targeted in 11 procedures and the left in 6, including 2 requiring bileaflet modification. Technical success was achieved in all cases (100%). Procedural success was achieved in 93.3%. One patient developed acute CO due to skirt-related occlusion after a high implant in a degenerated self-expanding valve, requiring single-vessel coronary artery bypass surgery. No bailout coronary stenting was required. There were no in-hospital deaths or disabling strokes. All patients were alive at 30-day follow-up. Conclusions: In this single-center experience, UNICORN appears technically reproducible, effective in preventing CO, and safe in TAVR patients at high-risk for CO.
Naguib et al. (Sat,) conducted a observational in High anatomic risk for coronary obstruction during transcatheter aortic valve replacement (n=15). UNICORN (Undermining Iatrogenic Coronary Obstruction with Radiofrequency Needle) assisted TAVR was evaluated on Technical success. UNICORN-assisted TAVR achieved 100% technical success and 93.3% procedural success in patients at high anatomic risk for coronary obstruction.