Answers are grounded in this paper and cite their sources.
Evaluates exergy output in flow-controlled PVT collectors, suggesting effective energy storage methods under variable conditions.
Photovoltaic–thermal (PVT) collectors co-generate electricity and heat—natural front ends for thermochemical energy storage (TCES)—provided the heat transfer fluid stays above the reactor’s desorption temperature. Using an eight-node model of a 0.6834 m2 collector at 8.64° N whose thermal core is partially validated against measured data from the same tropical–coastal site (rooftop PV module temperature, RMSE 3.8 °C; prototype absorber-to-water heat transfer, RMSE 1.3 °C), flow-regulated to the ≈95 °C SrCl2/NH3 desorption threshold, we quantify the energy and exergy delivered for charging under tropical–monsoon intermittency. The 95 °C setpoint operation, the ≈5.3 h charging window, and all reported exergy yields are simulated: the built prototype delivered hot water peaking at 79 °C and did not reach the 95 °C setpoint. On a measured clear-sky day (clearness index Kt = 0.52), the collector yields 1.38 kWh of energy but only 0.43 kWh of exergy (first-law efficiency ≈ 38%; gross exergy efficiency ≈ 13%); across a 30-seed synthetic-intermittency ensemble, the exergy yield is 0.678 kWh at ≈14% gross exergy efficiency (≈52% combined first-law efficiency). In both cases, the thermal stream dominates the energy output while the electrical stream dominates the exergy output—on the sunlit day, the exergy is about 80% electrical—because 95 °C heat carries a Carnot factor (exergetic quality factor, 1 − Ta/T7, at the instantaneous ambient dead state) of only ≈0.18 and an integrated Bejan/Kotas thermal-exergy quality of only ≈0.09. The controller holds the outlet within 1.4 K of the setpoint for ≈5.3 h, whereas no fixed flow in the 0.5–5.0 L min−1 range ever reaches it: feedback control is a structural enabler, not an optimisation. On overcast days, the threshold is never reached and charging heat collapses to zero, leaving a PV-only generator. Exergy delivery is nonetheless nearly controller-independent: the accumulated exergy delivery deficit after a 50% irradiance drop is 937 kJ, a controller-independent value changing only 1.3% across a systematic 4 × 4 gain sweep (Kp 0.33–2.7×, Kd 0.25–5× of nominal), and predictive control improves it by ≤1%. For PVT–TCES at this scale, the decisive lever is deployability, not control sophistication.
No takes yet. Share an insight, caveat, or question.
Rittiphet et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: