Why the study?
The clinical utility of routine electrocardiographic monitoring following PCI is not well studied.
Does routine continuous electrocardiographic monitoring following PCI identify actionable alarms that are associated with 30-day mortality?
Observational (n=1,672)
Does routine continuous electrocardiographic monitoring following PCI identify actionable alarms that are associated with 30-day mortality?
Actionable arrhythmia alarms following PCI are infrequent but associated with significantly higher 30-day mortality, and tailored monitoring per AHA guidelines could yield substantial cost savings.
Answers are grounded in this paper and cite their sources.
Actionable alarms were associated with higher post-PCI mortality; leaves open whether routine monitoring improves outcomes or warrants tailoring.
Background: The clinical utility of routine electrocardiographic monitoring following percutaneous coronary interventions (PCI) is not well studied. Methods: We prospectively evaluated the incidence, cost, and the clinical implications of actionable arrhythmia alarms on telemetry monitoring following PCI. One thousand three hundred fifty-eight PCI procedures (989 [72.8%] for acute coronary syndrome and 369 [27.2%] for stable angina) on patients admitted to nonintensive care unit were identified and divided into 2 groups; group 1, patients with actionable alarms (AA) and group 2, patients with non-AA. AA included (1) ≥3 s electrical pause or asystole; (2) high-grade Mobitz type II atrioventricular block or complete heart block; (3) ventricular fibrillation; (4) ventricular tachycardia (>15 beats); (5) atrial fibrillation with rapid ventricular response; (6) supraventricular tachycardia (>15 beats). Primary outcomes were 30-day all-cause mortality. Cost-savings analysis was performed. Results: Incidence of AA was 2.2% (37/1672). Time from end of procedure to AA was 5.5 (0.5, 24.5) hours. Patients with AA were older, presented with acute congestive heart failure or non–ST-segment–elevation myocardial infarction, and had multivessel or left main disease. The 30-day all-cause mortality was significantly higher in patients with AA (6.5% versus 0.3% in non-AA [ P <0.001]). Applying the standardized costing approach and tailored monitoring per the American Heart Association guidelines lead to potential cost savings of $622 480.95 for the entire population. Conclusions: AA following PCI were infrequent but were associated with increase in 30-day mortality. Following American Heart Association guidelines for monitoring after PCI can lead to substantial cost saving.
No takes yet. Share an insight, caveat, or question.
Al‐Hijji et al. (2019) conducted an observational in Post-percutaneous coronary intervention (n=1,672). Actionable arrhythmia alarms vs. Non-actionable alarms was evaluated on 30-day all-cause mortality (p=<0.001).