Key result
Calculating the preejection period using the Rpeak-B interval accounted for approximately 90% of the variance in standard Q-wave measurements at baseline and over 98% for reactivity values.
Why the study?
Does calculating the preejection period using the R wave peak instead of the Q wave provide an accurate estimate in young adults?
Observational (n=408)
Does calculating the preejection period using the R wave peak instead of the Q wave provide an accurate estimate in young adults?
Answers are grounded in this paper and cite their sources.
The Rpeak-B interval is a highly reliable and practical alternative to the traditional Q-B interval for estimating the preejection period, eliminating subjectivity and allowing measurement in patients without a visible Q wave.
Preejection period (PEP) is a common measure of sympathetic nervous system activation in psychophysiological research, which makes it important to measure reliably for as many participants as possible. PEP is typically calculated as the interval between the onset or peak of the electrocardiogram Q wave and the impedance cardiography B point, but the Q wave can lack clear definition and even its peak is not visible for all participants. We thus investigated the feasibility of using the electrocardiogram R wave peak (Rpeak ) instead of Q because it can be consistently identified with ease and precision. Across four samples (total N = 408), young adult participants completed a variety of minimally metabolically demanding laboratory tasks after a resting baseline. Results consistently supported a close relationship between absolute levels of the Rpeak -B interval and PEP (accounting for approximately 90% of the variance at baseline and 89% during task performance, on average), but for reactivity values, Rpeak -B was practically indistinguishable from PEP (accounting for over 98% of the variance, on average). Given that using Rpeak rather than the onset or peak of Q saves time, eliminates potential subjectivity, and can be applied to more participants (i.e., those without a visible Q wave), findings suggest that Rpeak -B likely provides an adequate estimate of PEP when absolute levels are of interest and clearly does so for within-person changes.
No takes yet. Share an insight, caveat, or question.
Seery et al. (2016) reported an observational. Rpeak-B interval measurement vs. Standard Q wave-based preejection period (PEP) measurement was evaluated on Variance in standard PEP accounted for by Rpeak-B interval (90% variance at baseline, 89% during tasks, 98% for reactivity). Calculating the preejection period using the Rpeak-B interval accounted for approximately 90% of the variance in standard Q-wave measurements at baseline and over 98% for reactivity values.
Synapse has enriched 10 related papers. Consider them for comparative context: