Key result
In anesthetized dogs, the position of maximal pulmonary blood flow normalized to fractional non-air was significantly different in supine versus prone positions (2.60 vs 5.08 cm, P<0.01).
Why the study?
Does body posture affect regional pulmonary blood flow distribution in anesthetized dogs as measured by 4D-X-ray CT?
Does body posture affect regional pulmonary blood flow distribution in anesthetized dogs as measured by 4D-X-ray CT?
Answers are grounded in this paper and cite their sources.
Normalization factors and body posture significantly affect the attribution of gravitational effects on pulmonary blood flow heterogeneity in dogs.
ECG-triggered computed tomography (CT) was used during passage of iodinated contrast to determine regional pulmonary blood flow (PBF) in anesthetized prone/supine dogs. PBF was evaluated as a function of height within the lung (supine and prone) as a function of various normalization methods: raw unit volume data (PBFraw) or PBF normalized to regional fraction air (PBFair), fractional non-air (PBFgm), or relative number of alveoli (PBFalv). The coefficient of variation of PBFraw, PBFair, PBFalv, and PBFgm ranged between 30 and 50% in both lungs and both body postures. The position of maximal flow along the height of the lung (MFP) was calculated for PBFraw, PBFair, PBFalv, and PBFgm. Only PBFgm showed a significantly different MFP height supine vs. prone (whole lung: 2.60 +/- 1.08 cm supine vs. 5.08 +/- 1.61 cm prone, P < 0.01). Mean slopes (ml/min/gm water content/cm) of PBFgm were steeper supine vs. prone in the right (RL) but not left lung (LL) (RL: -0.65 +/- 0.29 supine vs. -0.26 +/- 0.25 prone, P < 0.02; LL: -0.47 +/- 0.21 supine vs. -0.32 +/- 0.26 prone, P > 0.10). Mean slopes of PBFgm vs. vertical lung height were not different prone vs. supine above this vertical height of MFP (VMFP), but PBFgm slopes were steeper in the supine position below the VMFP in the RL. We conclude that PBFgm distribution was posture dependent in RL but not LL. Support of the heart may play a role. We demonstrate that normalization factors can lead to differing attributions of gravitational effects on PBF heterogeneity.
No takes yet. Share an insight, caveat, or question.
Chon et al. (2006) studied Anesthetized dogs. Supine position vs. Prone position was evaluated on Position of maximal flow along the height of the lung (MFP) for PBFgm (p=<0.01). In anesthetized dogs, the position of maximal pulmonary blood flow normalized to fractional non-air was significantly different in supine versus prone positions (2.60 vs 5.08 cm, P<0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: