Key result
During left bundle branch pacing, stimulus-to-peak of R wave in V6 abruptly shortened from LVSeP to NS-LBBP (76 ± 7 to 60 ± 4 ms, p<0.01), and late-R duration in V1 prolonged.
Why the study?
During left bundle branch pacing, various QRS morphologies occur as the lead penetrates the ventricular septum; this study evaluated these characteristics and their underlying mechanisms.
Observational (n=19)
p-value: p=<0.01
Prolonged late-R duration in V1 and abrupt shortening of s-LVAT in V6 can help determine left bundle branch capture during lead penetration.
BACKGROUND: In performing left bundle branch pacing (LBBP), various QRS morphologies are observed as the lead penetrates the ventricular septum (VS). This study aimed to evaluate these characteristics and infer the mechanism underlying each QRS morphology. METHODS: In 19 patients who met the strict criteria for LBB capture, we classified the QRS morphologies observed during the LBBP procedure into seven patterns, the first five of which were determined by the depth of penetration: right ventricular septal pacing (RVSP), intraventricular septal pacing (IVSP1 and IVSP2), endocardial side of left ventricular septal pacing (LVSeP), nonselective LBBP (NS-LBBP), selective LBBP (S-LBBP), and NS-LBBP with anodal capture. The parameters of the QRS morphologies in these seven patterns were evaluated. RESULTS: Among the first five patterns, stimulus-QRSend duration (s-QRSend) was the narrowest in IVSP1 rather than in NS-LBBP, and stimulus-to-peak of R wave in V6 (s-LVAT) was significantly shortened in two steps, from RVSP to IVSP1 (96 ± 11; 82 ± 8 ms, p < .01) and from LVSeP to NS-LBBP (76 ± 7; 60 ± 4 ms, p < .01). The late-R duration in V1 was significantly prolonged in the order of LVSeP, NS-LBBP, and S-LBBP (45 ± 7; 53 ± 10; 71 ± 15 ms, respectively, p < .01). CONCLUSIONS: s-QRSend was the narrowest in IVSP1 rather than in NS-LBBP among the QRS morphologies observed during lead penetration through the VS. The prolonged late-R duration in V1 and abrupt shortening of the s-LVAT in V6 may help determine LBB capture during lead penetration.
No takes yet. Share an insight, caveat, or question.
Shimeno et al. (2021) conducted an observational in Patients undergoing left bundle branch pacing (n=19). Left bundle branch pacing (LBBP) vs. Different depths of septal penetration (e.g., RVSP, LVSeP) was evaluated on QRS morphology parameters (s-QRSend, s-LVAT, late-R duration) (p=<0.01). During left bundle branch pacing, stimulus-to-peak of R wave in V6 abruptly shortened from LVSeP to NS-LBBP (76 ± 7 to 60 ± 4 ms, p<0.01), and late-R duration in V1 prolonged.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: