Answers are grounded in this paper and cite their sources.
A flow cytometric method (RAPID-B™) with detection sensitivity of one viable cell of Escherichia coli serotype O157:H7 in fresh spinach (Spinacia oleracea) was developed and evaluated. The major impediment to achieving this performance was mistaking autofluorescing spinach particles for tagged target cells. Following a 5 h non-selective enrichment, artificially inoculated samples were photobleached, using phloxine B as a photosensitizer. Samples were centrifuged at high speed to concentrate target cells, then gradient centrifuged to separate them from matrix debris. In external laboratory experiments, RAPID-B and the reference method both correctly detected E. coli O157:H7 at inoculations of ca. 15 cells. In a follow-up study, after 4 cell inoculations of positives and 6 h enrichment, RAPID-B correctly identified 92% of 25 samples. The RAPID-B method limit of detection (LOD) was one cell in 25 g. It proved superior to the reference method (which incorporated real time-PCR, selective enrichment, and culture plating elements) in accuracy and speed.