Answers are grounded in this paper and cite their sources.
Evaluates sensor quality and annealing effects on silicon sensors, indicating performance improvements.
We summarise Sensor Quality Control (SQC) results of non-irradiated silicon sensors for the CMS HGCAL detector, as well as the first detailed annealing campaign with a wafer-scale 120 µm (Epitaxial) sensor exposed to 2 × 10¹⁵ neq/cm² at the Rhode Island Nuclear Science Center (RINSC). For the non-irradiated sensors, we present an overview of the QC workflow developed for HGCAL, including automated handling of vendor data, validation of electrical measurements, and cross-checking of wafer-level characteristics. The study investigates, for the first time, the isothermal annealing behaviour at 60 °C after annealing periods ranging from 10 to 5000 minutes. Hamburg-model parameters for effective doping concentration changes with annealing time, extracted from full-sensor data, are presented. The post-irradiation behaviour of sensors with hot regions in the pre-irradiation leakage current measurements, as well as epitaxial sensors with stacking faults in individual cells, is also investigated.
No takes yet. Share an insight, caveat, or question.
group et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: