Key result
Prone back position ECG yields ~7-fold higher frequency of V1 Q waves versus supine ECG.
Why the study?
Guidance was needed for the clinical interpretation of ECGs in the prone position, including their electroanatomic explanations and whether prone back ECG can serve as an alternative to standard ECG.
Does prone back position ECG alter QRS amplitude, Q wave presence, and T-wave morphology compared to supine standard ECG?
Cross-Sectional (n=85)
Yes
Does prone back position ECG alter QRS amplitude, Q wave presence, and T-wave morphology compared to supine standard ECG?
Findings typical of myocardial infarction or low voltage on standard ECG (such as new Q waves and reduced QRS amplitude) are physiological artifacts in prone back ECGs and should not be misinterpreted as true pathology.
Answers are grounded in this paper and cite their sources.
Prone ECGs risk misinterpreting Q waves as pathology; leaves open need for position-specific diagnostic thresholds before clinical adoption.
AIMS: The aim of this study is to provide guidance for the clinical interpretation of electrocardiograms (ECGs) in prone position and to establish the electroanatomic explanations for the possible differences to supine position ECGs that may be observed. Additionally, to determine if prone back ECG can be used as an alternative to standard ECG in patients who may benefit from prone position. METHODS AND RESULTS: The ECG in supine (standard ECG), prone back (precordial leads placed on the patient's back), and prone anterior position (precordial leads placed in the standard position with the subjects in prone position) were prospectively examined on 85 subjects. Comparisons of ECG parameters between these positions were performed. Computed tomography (CT) scans were performed in both positions to determine possible electroanatomic aetiologies for prone-associated ECG changes. There were significant differences in QRS amplitude in Leads V1-V5 between supine and prone positions. Q waves were more frequently observed in prone back position vs. supine position (V1: 74.1 vs. 10.6%, P < 0.0001; V2: 23.5 vs. 0%, P < 0.0001, respectively). Flat and inverted T waves were more common in prone back leads (V1: 98 vs. 66%, P < 0.0001; V2: 96 vs. 8%, P < 0.0001; V3: 45 vs. 7%, P < 0.0001). The 3D-CT reconstructions measurements corroborated the significant inverse correlation between QRS amplitude and the distance from the centre of the heart to the estimated lead positions. CONCLUSION: In prone back position ECG, low QRS amplitude should not be misinterpreted as low voltage conditions, neither should Q waves and abnormal T waves are considered anteroseptal myocardial infarction. These changes can be explained by an increased impedance (due to interposing lung tissue) and by the increased distance between the electrodes to the centre of the heart.
No takes yet. Share an insight, caveat, or question.
Romero et al. (2022) conducted a cross-sectional in Acute respiratory distress syndrome (ARDS) and healthy volunteers (n=85). Prone back position ECG vs. Supine standard position ECG was evaluated on Frequency of Q waves in Lead V1 (p=<0.0001). Prone back position ECG increased the frequency of observed Q waves in lead V1 compared to supine position ECG.
Synapse has enriched 10 related papers. Consider them for comparative context: