Key result
First-time ICD implantation without defibrillation testing was noninferior to testing for first shock efficacy.
Why the study?
Does omitting intra-operative defibrillation testing impair first shock efficacy in patients undergoing first time ICD implantation?
RCT (n=1,077)
1:1
Yes
Does omitting intra-operative defibrillation testing impair first shock efficacy in patients undergoing first time ICD implantation?
Omitting defibrillation testing during first-time ICD implantation is non-inferior to testing for clinical shock efficacy, suggesting routine testing is no longer necessary.
Answers are grounded in this paper and cite their sources.
May support omitting defibrillation testing at first-time ICD implantation; leaves open need for randomized confirmation before practice change.
AIMS: This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS: Between February 2011 and July 2013, 1077 patients were randomly assigned (1 : 1) to first time ICD implantation with (n = 540) or without (n = 537) DF testing. The intra-operative DF testing was standardized across all participating centres, and all ICD shocks were programmed to 40 J irrespective of DF test results. The primary end point was the average first shock efficacy (FSE) for all true ventricular tachycardia and fibrillation (VT/VF) episodes during follow-up. The secondary end points included procedural data, serious adverse events, and mortality. During a median follow-up of 22.8 months, the model-based FSE was found to be non-inferior in patients with an ICD implanted without a DF test, with a difference in FSE of 3.0% in favour of the no DF test [confidence interval (CI) -3.0 to 9.0%, Pnon-inferiority <0.001 for the pre-defined non-inferiority margin of -10%). A total of 112 procedure-related serious adverse events occurred within 30 days in 94 patients (17.6%) tested compared with 89 events in 74 patients (13.9%) not tested (P = 0.095). CONCLUSION: Defibrillation efficacy during follow-up is not inferior in patients with a 40 J ICD implanted without DF testing. Defibrillation testing during first time ICD implantation should no longer be recommended for routine left-sided ICD implantation.
No takes yet. Share an insight, caveat, or question.
Bänsch et al. (2015) conducted an RCT in First time implantable cardioverter-defibrillator (ICD) implantation (n=1,077). ICD implantation without defibrillation testing vs. ICD implantation with defibrillation testing was evaluated on average first shock efficacy (FSE) for all true ventricular tachycardia and fibrillation (VT/VF) episodes during follow-up (Difference 3.0%, 95% CI -3.0 to 9.0, p=<0.001 for noninferiority). First-time ICD implantation without defibrillation testing was noninferior to testing for first shock efficacy.
Synapse has enriched 10 related papers. Consider them for comparative context: