Key result
Contact-force guided RF ablation did not significantly differ from cryoballoon ablation for arrhythmia recurrence in patients with a left common pulmonary vein (HR 1.19; 95% CI 0.53-2.65; P=0.69).
Why the study?
Concerns remain regarding the effectiveness of PVI using the fixed diameter non-compliant cryoballoon in the presence of a left common pulmonary vein (LCPV).
Does contact-force guided radiofrequency ablation reduce atrial tachyarrhythmia recurrence compared to cryoballoon ablation in patients with paroxysmal AF and a left common pulmonary vein?
RCT (n=346)
randomized
Does contact-force guided radiofrequency ablation reduce atrial tachyarrhythmia recurrence compared to cryoballoon ablation in patients with paroxysmal AF and a left common pulmonary vein?
Hazard Ratio: 1.19 (95% CI 0.53–2.65)
p-value: p=0.69
In patients with paroxysmal atrial fibrillation and a left common pulmonary vein, contact-force guided radiofrequency ablation and cryoballoon ablation provide similar rates of freedom from atrial tachyarrhythmia.
LCPV may trend toward higher recurrence after PVI; leaves open whether CF-RF or cryoballoon modifies outcomes in this anatomy.
BACKGROUND: Concerns remain regarding the effectiveness of PVI using the fixed diameter non-compliant cryoballoon in the presence of a left common pulmonary vein (LCPV). We sought to evaluate the effectiveness of PVI performed by contact-force guided radiofrequency (CF-RF) versus second-generation cryoballoon-based ablation in patients with LCPV. METHODS AND RESULTS: We enrolled 346 patients with paroxysmal AF and randomized them to CF-RF or cryoballoon ablation. PV anatomy was not assessed prior to enrolment, and there were no exclusions based on PV anatomy. All patients received an implantable cardiac monitor. LCPV was observed in 13.6% of patients (47/346). Left atrial time and fluoroscopy time did not differ between those with and without LCPV (P=0.58 and P=0.06, respectively). Freedom from any atrial tachyarrhythmia at one year was observed in 46.8% with LCPV and 54.5% without LCPV (P=0.06). In those with LCPV the freedom from any atrial tachyarrhythmia did not differ between those randomized to CF-RF or cryoballoon ablation (HR for recurrence 1.19, 95% CI 0.53-2.65, P=0.69). In those with LCPV the AF burden was reduced to a similar extent with CF-RF and cryoballoon ablation (99.7% vs. 99.5%, respectively; P=0.97). CONCLUSIONS: In this randomized clinical trial, the presence of a LCPV was associated with a trend towards higher rates of arrhythmia recurrence following PVI. No significant difference in arrhythmia recurrence was observed between patients with LCPV randomized to cryoballoon ablation or contact-force guided RF ablation, suggesting that either ablation modality is suitable in this population. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE], NCT01913522) This article is protected by copyright. All rights reserved.
No takes yet. Share an insight, caveat, or question.
Larsen et al. (2020) conducted an RCT in paroxysmal atrial fibrillation (n=346). Contact-force guided radiofrequency (CF-RF) ablation vs. Cryoballoon ablation was evaluated on Arrhythmia recurrence (HR 1.19, 95% CI 0.53-2.65, p=0.69). Contact-force guided RF ablation did not significantly differ from cryoballoon ablation for arrhythmia recurrence in patients with a left common pulmonary vein (HR 1.19; 95% CI 0.53-2.65; P=0.69).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: