Key result
Ultra-wideband radar using a deep transfer learning algorithm estimated children's heart and respiratory rates with a mean absolute error of 7.3 beats per minute and 2.63 breaths per minute.
Why the study?
Unobtrusive monitoring of children's heart rate and respiratory rate can promote early detection of health issues, but effective wireless monitoring methods are needed.
Does ultra-wideband radar with deep transfer learning accurately estimate heart rate and respiratory rate in children?
Observational (n=55)
Does ultra-wideband radar with deep transfer learning accurately estimate heart rate and respiratory rate in children?
Effect estimate: MAE 7.3 BPM for HR, 2.63 breaths/min for RR
Ultra-wideband radar combined with deep transfer learning provides a promising unobtrusive method for monitoring heart and respiratory rates in children.
May support unobtrusive pediatric HR/RR monitoring; hypothesis-generating and leaves open larger validation trials.
Unobtrusive monitoring of children's heart rate (HR) and respiratory rate (RR) can be valuable for promoting the early detection of potential health issues, improving communication with healthcare providers and reducing unnecessary hospital visits. A promising solution for wireless vital sign monitoring is radar technology. This paper presents a novel approach for the simultaneous estimation of children's RR and HR utilizing ultra-wideband (UWB) radar using a deep transfer learning algorithm in a cohort of 55 children. The HR and RR are calculated by processing radar signals via spectrogram from time epochs of 10 s (25 sample length of hamming window with 90% overlap) and then transforming the resultant representation into 2-dimensional images. These images were fed into a pre-trained Visual Geometry Group-16 (VGG-16) model (trained on ImageNet dataset), with weights of five added layers fine-tuned using the proposed data. The prediction on the test data achieved a mean absolute error (MAE) of 7.3 beats per minute (BPM < 6.5% of average HR) and 2.63 breaths per minute (BPM < 7% of average RR). We also achieved a significant Pearson's correlation of 77% and 81% between true and extracted for HR and RR, respectively. HR and RR samples are extracted every 10 s.
No takes yet. Share an insight, caveat, or question.
Arasteh et al. (2023) conducted an observational in Early childhood (n=55). Ultra-wideband (UWB) radar with deep transfer learning vs. True heart rate and respiratory rate was evaluated on Mean absolute error (MAE) and Pearson's correlation for HR and RR (MAE 7.3 BPM for HR, 2.63 breaths/min for RR). Ultra-wideband radar using a deep transfer learning algorithm estimated children's heart and respiratory rates with a mean absolute error of 7.3 beats per minute and 2.63 breaths per minute.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: