Key result
Latest generation transcatheter heart valves have reduced major vascular events and paravalvular leaks, but thromboembolic events remain unchanged and conduction disturbances have slightly increased.
Why the study?
Technical and design iterations of transcatheter valve systems have reduced adverse events and improved outcomes, warranting an overview of latest generation devices focused on early safety and efficacy.
What are the relative safety and efficacy outcomes of different latest generation transcatheter heart valves in patients with severe aortic stenosis?
What are the relative safety and efficacy outcomes of different latest generation transcatheter heart valves in patients with severe aortic stenosis?
While newer TAVR devices have reduced vascular complications and paravalvular leaks, stroke rates remain unchanged and pacemaker requirements have slightly increased, highlighting areas for future iteration.
Latest THV designs show favorable early TAVR outcomes; leaves open durability and low-risk expansion questions.
INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is a well-established treatment for patients with severe aortic stenosis and intermediate-to-high surgical risk. The increasing clinical experience along with technical and design iterations of transcatheter valve systems have contributed to reducing adverse events and improving clinical outcomes. AREAS COVERED: Overview of the latest generation transcatheter heart valves (THVs), focusing on early safety and efficacy outcomes. EXPERT COMMENTARY: Improvements in valve repositionability, reducing the size of valve delivery systems, and antiparavalvular leak iterations have contributed to improving the safety and clinical outcomes following TAVR. However, while certain complications like major vascular events and residual paravalvular leaks have significantly decreased with the arrival of newer generation THVs, no major changes in thromboembolic events (particularly stroke) have been observed, whereas other complications like conduction disturbances requiring pacemaker implantation have slightly increased over time. Also, no major progress on device retrievability has been observed in the last years. The expansion of TAVR toward the treatment of younger and lower risk patients, as well as newer indications (e.g. asymptomatic patients) will likely require an extra-effort involving additional device iterations and complementary therapies (e.g. embolic protection, newer vascular closure devices) to further improve safety and clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Val et al. (2018) conducted a review in Severe aortic stenosis. Transcatheter aortic valve replacement (TAVR) was evaluated. Latest generation transcatheter heart valves have reduced major vascular events and paravalvular leaks, but thromboembolic events remain unchanged and conduction disturbances have slightly increased.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: