Key result
Chronic renal dysfunction (OR 1.30; 95% CI 1.16-1.57) and repeated procedures (OR 1.23; 95% CI 1.12-1.42) were independently associated with a higher risk of CIED infection.
Why the study?
Do repeated procedures and chronic renal dysfunction increase the risk of device infections in patients undergoing CIED implantation or revision?
Observational (n=3,899)
No
Do repeated procedures and chronic renal dysfunction increase the risk of device infections in patients undergoing CIED implantation or revision?
Odds Ratio: 1.3 (95% CI 1.16–1.57)
p-value: p=<0.0001
In patients undergoing CIED procedures, chronic renal dysfunction and redo procedures are significant independent risk factors for device infections, which are predominantly caused by Staphylococcal species.
Supports targeted infection prevention in CIED patients with renal dysfunction or repeats; leaves open need for prospective validation.
BACKGROUND: Infection is a major complication of pacemaker (PM) and implantable cardioverter-defibrillator (ICD) implantation. The present study sought to analyze the incidence rate of device infections, to investigate possible relationships between first implantations/repeated procedures and infection rates, and to identify some main risk factors associated with infection of cardiac implantable electronic devices (CIED). METHODS: In a single center retrospective observational study, records of 3899 consecutive patients having undergone PM and ICD implantation, cardiac resynchronization therapy (CRT) or revision (device/lead replacements or upgrades) and between 2002 and 2012 were obtained. RESULTS: Over a mean follow-up period of 66±14 months, a total of 50 patients were identified as having CIED infection (0.85% per procedure and 1.28% per patient). Chronic renal dysfunction and repeated procedures were independently associated with higher risk of CIED infection on multivariate analysis (respectively, OR 1.30, 95% CI: 1.16-1.57, P<0.0001; OR 1.23, 95% CI: 1.12-1.42, P<0.0001). Staphylococcal species was responsible for the bulk of CIED infections (70% of all positive cultures). Coagulase-negative staphylococci were found more frequently than staphylococcus aureus (30% vs. 12%). CONCLUSIONS: The infection rate after cardiac electronic device procedures was low over the follow-up period. Repeated procedures and chronic renal dysfunction were associated with higher risk of CIED infection. Staphylococcal species were mainly responsible for device infections.
No takes yet. Share an insight, caveat, or question.
Morani et al. (2018) conducted an observational in Cardiac implantable electronic device (CIED) implantation or revision (n=3,899). Chronic renal dysfunction and repeated procedures was evaluated on CIED infection (OR 1.30, 95% CI 1.16-1.57, p=<0.0001). Chronic renal dysfunction (OR 1.30; 95% CI 1.16-1.57) and repeated procedures (OR 1.23; 95% CI 1.12-1.42) were independently associated with a higher risk of CIED infection.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: