Key result
Aortic pulse wave velocity measured by flow-sensitive 4D MRI was higher in patients with aortic atherosclerosis compared to volunteers.
Why the study?
Does flow-sensitive 4D MRI reliably measure aortic pulse wave velocity and correlate with clinical characteristics in patients with aortic atherosclerosis?
Observational (n=98)
Does flow-sensitive 4D MRI reliably measure aortic pulse wave velocity and correlate with clinical characteristics in patients with aortic atherosclerosis?
Flow-sensitive 4D MRI is a reproducible method for estimating aortic pulse wave velocity, which is elevated in patients with aortic atherosclerosis and correlates with age, aortic valve insufficiency, and pulse pressure.
Answers are grounded in this paper and cite their sources.
4D MRI aortic PWV measurement shows reliability in volunteers; leaves open its prognostic role in atherosclerosis.
PURPOSE: To measure aortic pulse wave velocity (PWV) using flow-sensitive four-dimensional (4D) MRI and to evaluate test-retest reliability, inter- and intra-observer variability in volunteers and correlation with characteristics in patients with aortic atherosclerosis. MATERIALS AND METHODS: Flow-sensitive 4D MRI was performed in 12 volunteers (24 ± 3 years) and 86 acute stroke patients (68 ± 9 years) with aortic atherosclerosis. Retrospectively positioned 28 ± 4 analysis planes along the entire aorta (inter-slice-distance = 10 mm) and frame wise lumen segmentation yielded flow-time-curves for each plane. Global aortic PWV was calculated from time-shifts and distances between the upslope portions of all available flow-time curves. RESULTS: Inter- and intra-observer variability of PWV measurements in volunteers (7% and 8%) was low while test-retest reliability (22%) was moderate. PWV in patients was significantly higher compared with volunteers (5.8 ± 2.9 versus 3.8 ± 0.8 m/s; P = 0.02). Among 17 patient characteristics considered, statistical analysis revealed significant (P < 0.05) but low correlation of PWV with age (r = 0.25), aortic valve insufficiency (r = 0.29), and pulse pressure (r = 0.28). Multivariate modeling indicated that aortic valve insufficiency and elevated pulse pressure were significantly associated with higher PWV (adjusted R(2) = 0.13). CONCLUSION: Flow-sensitive 4D MRI allows for estimating aortic PWV with low observer dependence and moderate test-retest reliability. PWV in patients correlated with age, aortic valve insufficiency, and pulse pressure.
No takes yet. Share an insight, caveat, or question.
Markl et al. (2012) conducted an observational in Aortic atherosclerosis (n=98). Flow-sensitive four-dimensional (4D) MRI vs. Volunteers was evaluated on Aortic pulse wave velocity (PWV) (p=0.02). Aortic pulse wave velocity measured by flow-sensitive 4D MRI was higher in patients with aortic atherosclerosis compared to volunteers.
Synapse has enriched 10 related papers. Consider them for comparative context: