Key result
Right-sided double valve replacement using bioprostheses was successfully performed in a 56-year-old woman with severe pulmonary and tricuspid regurgitation, resulting in an uneventful one-year follow-up without prosthetic valve dysfunction.
Why the study?
Postoperative worsening or recurrence of tricuspid regurgitation is a major concern following pulmonary valve replacement combined with tricuspid annuloplasty in adult patients with previous pulmonary valvular surgery.
Case Report (n=1)
No
Tricuspid valve replacement rather than annuloplasty may be considered for severe functional tricuspid regurgitation associated with right ventricular dilatation and tethering after previous pulmonary valve surgery.
Answers are grounded in this paper and cite their sources.
Successful right-sided bioprosthetic double valve replacement in one case; leaves open comparative efficacy versus annuloplasty in severe functional TR.
BACKGROUND: Pulmonary regurgitation and the subsequent functional tricuspid regurgitation are frequently observed in adult patients who previously underwent pulmonary valvular operations. Pulmonary valve replacement, in combination with tricuspid annuloplasty, is frequently performed in adult patients. However, postoperative worsening or recurrence of tricuspid regurgitation is a major concern after pulmonary valve replacement with tricuspid annuloplasty. CASE PRESENTATION: Herein, we describe the case of a 56-year-old woman with severe pulmonary regurgitation and functional tricuspid regurgitation after congenital pulmonary stenosis surgery in childhood. Functional tricuspid regurgitation was due to tricuspid annular dilatation, marked right ventricle enlargement, and significant tethering. We performed a bioprosthetic double valve replacement, and the postoperative course was uneventful. The patient is doing well one year after the surgery without prosthetic valve dysfunction. CONCLUSIONS: When functional tricuspid regurgitation is severe and is associated with right ventricular dilatation and subsequent tethering, tricuspid valve replacement rather than annuloplasty should be considered.
No takes yet. Share an insight, caveat, or question.
Kobayashi et al. (2020) conducted a case report in Severe pulmonary regurgitation and functional tricuspid regurgitation (n=1). Right-sided double valve replacement (bioprosthetic) was evaluated on Postoperative recovery and prosthetic valve function. Right-sided double valve replacement using bioprostheses was successfully performed in a 56-year-old woman with severe pulmonary and tricuspid regurgitation, resulting in an uneventful one-year follow-up without prosthetic valve dysfunction.
Synapse has enriched 10 related papers. Consider them for comparative context: