Key result
Staggered electrode grids improve omnipolar electrogram reconstruction and fibrotic tissue classification over rectangular grids.
Why the study?
Given advances in high-density catheter design offering alternative spatial electrode arrangements, the study evaluated the performance of alternative clique geometries from staggered electrode grids for omnipolar electrogram estimation.
Do staggered electrode grid configurations improve omnipolar electrogram reconstruction and fibrotic tissue classification compared to rectangular grids in in silico models?
Do staggered electrode grid configurations improve omnipolar electrogram reconstruction and fibrotic tissue classification compared to rectangular grids in in silico models?
Staggered electrode configurations, particularly rhomboid and hexagonal geometries, improve omnipolar electrogram reconstruction and fibrotic tissue classification in computational models compared to standard rectangular grids.
May refine omnipolar mapping accuracy in ablation; leaves open prospective outcome trials.
Background and Objective: Accurate characterization of the cardiac substrate through multi-electrode catheters allows for the reconstruction of electroanatomical maps, guiding and optimizing ablation procedures. Omnipolar electrogram (oEGM) technology represents a significant advancement, allowing for orientation-independent tissue assessment. Given the advances in high-density catheter design offering alternative spatial electrode arrangements, the main aim of this study is to evaluate the performance of alternative clique geometries derived from a staggered grid of electrodes for oEGM estimation. Methods: Three clique configurations, including the regular triangular, rhomboid and hexagonal geometries were geometrically derived for staggered electrode grids for electric field estimation. Their performance was assessed using physiologically based in silico simulations, with controlled variations in anisotropy, tissue inhomogeneities, catheter orientation and interelectrode spacing. Reconstruction quality was quantified using the Residual-to-omnipolar ratio ( ROR ) and local activation time error ( ϵ LAT ), with a sensitivity analysis to different noise levels and angular characterization. Additionally, fibrotic tissue classification was evaluated using oEGM amplitudes through multiple lesion sizes. Results: The proposed methodologies generally improved oEGM reconstruction robustness compared with the conventional approaches although the cross configuration in rectangular grids remained competitive. Under healthy conditions, the hexagonal and rhomboid configurations generally provided the lowest ROR and ϵ LAT values, with reduced sensitivity to catheter orientation. In fibrotic tissue, the rhomboid clique showed the lowest reconstruction error. For fibrotic tissue classification, staggered configurations achieved higher sensitivity than rectangular grids through greater spatial sampling density, albeit at the expense of specificity. Conclusions: Three novel clique configurations for oEGM estimation in a staggered electrode array were proposed and evaluated. The results show improvements over standard rectangular grid approaches in both reconstruction quality and fibrotic tissue classification, highlighting the importance of balancing reconstruction performance, spatial coverage and electrode configuration. These results support the development of catheters with progressively reduced interelectrode spacing and optimized electrode geometries, subject to further clinical validation.
No takes yet. Share an insight, caveat, or question.
Alós‐Maldonado et al. (2026) studied Cardiac electrophysiology mapping. Staggered arrangement of high-density multielectrodes (triangular, rhomboid, hexagonal) vs. Standard rectangular grid approaches was evaluated on Residual-to-omnipolar ratio (ROR) and local activation time error (ϵLAT). Staggered electrode configurations, particularly hexagonal and rhomboid geometries, improved omnipolar electrogram reconstruction quality and fibrotic tissue classification over rectangular grids.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: