Key result
Four direct current countershocks of 200 J each delivered via an electrode catheter successfully abolished recurrent ventricular tachycardia, with no recurrence at 12 months.
Case Report (n=1)
Direct current catheter ablation successfully treated recurrent ventricular tachycardia caused by triggered activity.
Answers are grounded in this paper and cite their sources.
Suggests mechanism-specific verapamil use in select tachycardias; leaves open validation in larger cohorts before practice change.
Triggered activity was shown to be the likely mechanism of recurrent tachycardia in a 28 year old Vietnamese man. During baseline electrophysiological testing the tachycardia was induced consistently by prolonged atrial or ventricular pacing but not by premature extrastimuli. Moreover, the tachycardia coupling intervals varied directly with the cycle length of the initiating drive. Procainamide and propranolol did not suppress tachycardia, but verapamil terminated it and prevented its reinitiation. The origin of the tachycardia was localised to the left ventricular inferoapical segment and four direct current countershocks of 200 J each delivered via an electrode catheter abolished the tachycardia. During 12 months of follow up the patient was not treated with antiarrhythmic agents and the tachycardia did not recur.
No takes yet. Share an insight, caveat, or question.
Bhandari et al. (1988) conducted a case report in Recurrent ventricular tachycardia (n=1). Direct current countershocks via electrode catheter was evaluated on Tachycardia recurrence. Four direct current countershocks of 200 J each delivered via an electrode catheter successfully abolished recurrent ventricular tachycardia, with no recurrence at 12 months.
Synapse has enriched 10 related papers. Consider them for comparative context: